Effect of attachment flash on clear aligner force delivery: an in vitro study
Marisa Kiong1, Asma Ashari2, Nurul Syahira Mohamad Zamani3
1Department of Family Oral Health, Faculty of Dentistry, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abdul Aziz, 50300, Kuala Lumpur, Malaysia.
BMC Oral Health
|May 7, 2024
Summary
Excess resin flash around clear aligner attachments does not significantly alter force delivery. Rectangular attachments generate more force than ellipsoidal ones, regardless of flash presence.
Area of Science:
- Orthodontics
- Biomaterials Engineering
- Dental Mechanics
Background:
- Clear aligner (CA) therapy effectiveness is enhanced by composite attachments.
- Attachment placement can lead to resin flash, potentially impacting CA force delivery.
- Understanding the effect of flash on attachment force is crucial for optimizing CA treatment.
Purpose of the Study:
- To investigate the impact of resin flash on the force generated by clear aligner attachments.
- To compare the force delivery of ellipsoidal and rectangular attachments with and without flash.
- To determine if flash significantly affects the mechanical performance of clear aligner attachments.
Main Methods:
- Fabrication of clear aligners using Tristar Trubalance sheets and 3D-printed resin models.
- Bonding of 17 ellipsoidal and 17 rectangular attachments to maxillary right central incisors.
- Quantification of attachment forces using Fuji Prescale pressure film and a calibrated pressure mapping system, both before and after flash removal.
Main Results:
- No statistically significant difference in mean force was observed for either ellipsoidal (p=0.07) or rectangular attachments (p=0.41) in the presence or absence of flash.
- Rectangular attachments generated significantly higher mean forces than ellipsoidal attachments (p<0.001), irrespective of flash.
- The study demonstrated high reliability in force measurements (ICC=0.96).
Conclusions:
- The presence or absence of resin flash around clear aligner attachments does not significantly alter their force generation capabilities.
- Rectangular attachments provide superior force delivery compared to ellipsoidal attachments.
- Clinical implications suggest that minor flash may not compromise clear aligner treatment efficacy related to attachment force.