Evaluation of micropillar array columns for chromatographic separation of phosphorothioated oligonucleotides and
Lieve Dillen1, Tiny Deschrijver2, Kurt Van Mol3
1Drug Metabolism and Pharmacokinetics Janssen R&D Beerse Belgium.
Abstract:
Chromatographic analysis of therapeutic oligonucleotides is challenging due to the presence of closely related impurities, degradants or metabolites and due to the presence of phosphorothioate bonds, which introduce chiral centers. In the present study, ion pair reversed phase chromatography of oligonucleotides on micropillar array columns was investigated. Two commonly used mobile phase conditions were included. With 16.3 mM triethylamine and 400 mM hexafluoroisopropanol, the separation of 16-mer oligonucleotides differing in the number and positions of phosphorothioate linkages as well as some n-1 and n-2 truncations demonstrated complete suppression of diastereoselectivity. Although the positional phosphorothioate isomers evaluated could not be resolved, an increase in phosphorothioate bonds resulted in more retention. A therapeutic 19-mer RNA sequence with 2'-fluor and 2'-O-methyl modifications showed partial separation of some very close impurities. When using 15 mM triethyl ammonium acetate in the mobile phase, diastereomer selectivity was clearly observed for all analytes. The best result was obtained for the 19-mer RNA therapeutic mimic with four phosphorothioate bonds, since all 16 theoretical diastereomers were clearly observed under the conditions tested. A limited benchmark exercise demonstrated the improved capability of the new micropillar array columns. Therefore, these columns can be positioned as a valuable alternative when challenging oligonucleotide separations are expected.
Related Concept Videos
Principles Of Column Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Affinity Chromatography