A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Thrombus discrimination with electron density: potential implications for non-contrast computed tomography imaging
Gaston A Rodriguez-Granillo1, Juan Cirio2, Celina Morales3
1Department of Cardiovascular Imaging, Instituto Medico ENERI, Clinica La Sagrada Familia, Buenos Aires, Argentina.
Abstract:
The potential clinical usefulness of electron density (ED) imaging, that can be directly estimated using dual-layer spectral computed tomography (CT), has been poorly investigated. We explored whether ED imaging might improve thrombus identification compared to conventional imaging in vitro. We evaluated mechanical thrombectomy material obtained from patients with acute ischemic stroke (AIS) treated in a tertiary level stroke center and immediately fixed in 10% neutral buffered formalin and stored in polystyrene test tubes. The test tubes were immersed in a bucket of water for evaluation by spectral CT, along with scattered control tubes. All images were obtained using a dual-layer detector CT scanner. Each tube was assessed using multiparametric side-by-side view of conventional CT (120 kVp), low monoenergetic imaging (40 keV), and ED images. Fifty-eight polystyrene tubes were analyzed, comprising 52 tubes with thrombectomy material of at least 1 mm2 size obtained from 52 AIS patients, and six control tubes filled with formalin. ED imaging identified accurately the presence of material in all tubes, whereas 2 (3%) of the tubes containing thrombus were not identified by conventional CT, leading to a very good agreement between observers for the presence of material using conventional CT and ED imaging (kappa =0.84, P<0.001). Using ED imaging, thrombus material showed a mean density of 108.8±2.9 percent ED relative to water (%EDW), water had a mean density of 100.0±0.3 %EDW, and formalin a mean density of 103.5±1.2 %EDW. Compared to conventional imaging and 40 keV monoenergetic, ED imaging had a significantly higher signal-to-noise ratio (conventional 10.4±7.0, vs. 40 keV 11.5±8.4, vs. ED 490.0±304.5, P<0.001) and contrast-to-noise ratio (CNR) (conventional 4.3±4.3, vs. 40 keV 5.7±11.2, vs. ED 37.8±29.1, P<0.001). In this in-vitro study, we demonstrated improved visualization of thrombus with ED imaging compared to conventional imaging and low monoenergetic imaging, with a significant increase in CNR.
More Related Videos
13:10Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...