Spectroscopic, electrochemical, and kinetic trends in Fe(III)-thiolate disproportionation near physiologic pH

Levi A Ekanger1, Ruhi K Shah2, Matthew E Porowski2

  • 1Department of Chemistry, The College of New Jersey, Ewing, NJ, 08628, USA. ekangerl@tcnj.edu.

Related Concept Videos

Ladder Diagrams: Redox Equilibria01:30

Ladder Diagrams: Redox Equilibria

Ladder diagrams are useful tools for understanding redox equilibrium reactions, especially the effects of concentration changes on the electrochemical potential of the reaction. The vertical axis in the redox ladder diagrams represents the electrochemical potential, E. The area of predominance is demarcated using the Nernst equation.
Consider the Fe3+/Fe2+ half-reaction, which has a standard-state potential of +0.771 V. At potentials more positive than +0.771 V, Fe3+ predominates, whereas Fe2+...
451
Preparation and Reactions of Thiols02:33

Preparation and Reactions of Thiols

Thiols are prepared using the hydrosulfide anion as a nucleophile in a nucleophilic substitution reaction with alkyl halides. For instance, bromobutane reacts with sodium hydrosulfide to give butanethiol.
6.2K
Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
1.7K
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
272
Titration of a Polyprotic Acid02:08

Titration of a Polyprotic Acid

A polyprotic acid contains more than one ionizable hydrogen and undergoes a stepwise ionization process.  If the acid dissociation constants of the ionizable protons differ sufficiently from each other, then the titration curve for such polyprotic acid generates a distinct equivalence point for each of its ionizable hydrogens. Therefore, titration of a diprotic acid results in the formation of two equivalence points, whereas the titration of a triprotic acid results in the formation of three...
96.5K
Redox Titration: Other Oxidizing and Reducing Agents01:26

Redox Titration: Other Oxidizing and Reducing Agents

Besides iodine, other oxidizing or reducing agents can serve as titrants in redox titrations. Common oxidizing titrants include KMnO4, cerium(IV), and K2Cr2O7. The choice of oxidizing titrants depends on factors like stability, cost, analyte strength, and reaction rate between the analyte and titrant. KMnO4 is a strong oxidizing titrant that reduces from Mn(VII) to Mn(II) in a highly acidic solution, simultaneously oxidizing the analyte to a higher oxidation state. In this case, KMnO4 acts as a...
278