Related Experiment Video
Updated: Jun 26, 2025

Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
VA-ECMO weaning strategy using adjusted pulse pressure by vasoactive inotropic score in AMI complicated by
Bo Ram Lee1, Ki Hong Choi2, Eun Jin Kim2
1Department of Medical Device Management and Research, SAIHST, Sungkyunkwan University, Seoul, Republic of Korea.
Aims:
This study evaluated how well serial pulse pressure (PP) and PP adjusted by the vasoactive inotropic score (VIS) predicted venoarterial extracorporeal membrane oxygenation (VA-ECMO) weaning success and clinical outcomes in acute myocardial infarction complicated by cardiogenic shock (AMI-CS) patients.
Methods And Results:
A total of 213 patients with AMI-CS who received VA-ECMO between January 2010 and August 2021 were enrolled in the institutional ECMO registry. Serial PP and VIS were measured immediately, 12, 24, and 48 h after VA-ECMO insertion. PP adjusted by VIS was defined as PP/√VIS. The primary outcome was successful VA-ECMO weaning. Successful weaning from VA-ECMO was observed in 151 patients (70.9%). Immediately after VA-ECMO insertion, PP [successful vs. failed weaning, 26.0 (15.5-46.0) vs. 21.0 (12.5-33.0), P = 0.386] and PP/√VIS [11.1 (5.1-25.0) vs. 6.0 (3.1-14.2), P = 0.118] did not differ between the successful and failed weaning groups. Serial PP and PP adjusted by VIS at 12, 24, and 48 h after VA-ECMO insertion were significantly higher in patients with successful weaning than those with failed weaning [successful vs. failed weaning, 24.0 (4.0-38.0) vs. 12.5 (6.0-25.5), P = 0.007 for 12 h PP, and 10.1 (5.7-22.0) vs. 2.9 (1.7-5.9), P < 0.001 for 12 h PP/√VIS]. The 12 h PP/√VIS showed better discriminative function for successful weaning than 12 h PP alone [area under the curve (AUC) 0.80, 95% confidence interval (CI) 0.72-0.88, P < 0.001 vs. AUC 0.67, 95% CI 0.57-0.77, P = 0.002]. Patients with a low 12 h PP/√VIS (≤7) had higher rates of in-hospital mortality (44.4% vs. 19.8%, P < 0.001) and 6 month follow-up mortality (hazard ratio 2.41, 95% CI 1.49-3.90, P < 0.001) than those with a high 12 h PP/√VIS (>7).
Conclusions:
PP adjusted by VIS taken 12 h following VA-ECMO initiation can predict weaning from VA-ECMO more successfully than PP alone, and its low value was associated with a higher risk of mortality in AMI-CS patients.
More Related Videos
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
Related Concept Videos
Heart Failure Drugs: Inotropic Agents
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Decreased pulse rate
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...