Related Experiment Video
Updated: May 5, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Microstructural investigation of hybrid CAD/CAM restorative dental materials by micro-CT and SEM
Elisabeth Prause1, Jeremias Hey2, Florian Beuer1
1Department of Prosthodontics, Geriatric Dentistry and Craniomandibular Disorders, Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Aßmannshauser Str. 4-6, 14197 Berlin, Germany.
Objectives:
An increasing number of CAD/CAM (computer-aided design/computer-aided manufacturing) hybrid materials have been introduced to the dental market in recent years. In addition, CAD/CAM hybrid materials for additive manufacturing (AM) are becoming more attractive in digital dentistry. Studies on material microstructures using micro-computed tomography (µ-CT) combined with scanning electron microscopy (SEM) have only been available to a limited extent so far.
Methods:
One CAD/CAM three-dimensional- (3D-) printable hybrid material (VarseoSmile Crown plus) and two CAD/CAM millable hybrid materials (Vita Enamic; Voco Grandio), as well as one direct composite material (Ceram.x duo), were included in the present study. Cylindrical samples with a diameter of 2 mm were produced from each material and investigated by means of synchrotron radiation µ-CT at a voxel size of 0.65 µm. Different samples from the same materials, obtained by cutting and polishing, were investigated by SEM.
Results:
The 3D-printed hybrid material showed some agglomerations and a more irregular distribution of fillers, as well as a visible layered macrostructure and a few spherical pores due to the printing process. The CAD/CAM millable hybrid materials revealed a more homogenous distribution of ceramic particles. The direct composite material showed multiple air bubbles and microstructural irregularities based on manual processing.
Significance:
The µ-CT and SEM analysis of the materials revealed different microstructures even though they belong to the same class of materials. It could be shown that µ-CT and SEM imaging are valuable tools to understand microstructure and related mechanical properties of materials.