Do Hounsfield Units From Intraoperative CT Scans Correlate With Preoperative Values?
Brendan M Striano1, Alexander M Crawford1, Harry M Lightsey1
1Harvard Combined Orthopaedic Residency Program, Harvard Medical School, Boston, MA, USA.
Intraoperative CT scans allow for reliable measurement of vertebral Hounsfield units, but these bone density values do not correlate with preoperative measurements. Therefore, intraoperative Hounsfield units should not be used interchangeably with preoperative values for prognostic purposes.
Area of Science:
- Spine surgery
- Medical imaging
- Bone density assessment
Background:
- Increasing interest in forecasting postoperative complications using bone density metrics.
- Vertebral Hounsfield units from opportunistic CT scans show promise for bone density assessment.
- Intraoperative advanced imaging is increasingly adopted in spine surgery.
Purpose of the Study:
- Assess the reliability of measuring vertebral Hounsfield units from intraoperative CT scans.
- Determine if intraoperative Hounsfield unit measurements correlate with preoperative CT scan values.
Main Methods:
- Retrospective study of 81 patients undergoing instrumented spinal fusion with intraoperative CT.
- Two physician reviewers measured vertebral Hounsfield units from preoperative and intraoperative CT scans.
- Interrater reliability, intraclass correlation, repeated measures correlation, and linear mixed models were used for analysis.
Main Results:
- Vertebral Hounsfield units can be reliably measured from intraoperative CT scans with good interrater concordance (correlation=0.82).
- No correlation was found between Hounsfield units measured from intraoperative CT scans and preoperative CT scans (r=0.01).
- This lack of correlation persisted even after controlling for patient and clinical factors.
Conclusions:
- Measuring Hounsfield units from intraoperative CT scans is feasible and reliable.
- Intraoperative Hounsfield unit measurements do not correlate with preoperative values and should not be used interchangeably.
- Future research should investigate the prognostic value of intraoperative Hounsfield units as a distinct metric.