Experimental Study on Dynamic Mechanical Performance of Post-Fire Concrete Confined by CFRP Sheets
Jingya Liu1, Jingsi Huo2, Haitao Wang3,4
1Institute of Structural Material Failure and Strengthening Technology, Ningbo Polytechnic, Ningbo 315800, China.
Abstract:
Impact tests on post-fire concrete confined by Carbon Fiber-Reinforced Polymer/Plastic (CFRP) sheets were carried out by using Split Hopkinson Pressure Bar (SHPB) experimental setup in this paper, with emphasis on the effect of exposed temperatures, CFRP layers and impact velocities. Firstly, according to the measured stress-strain curves, the effects of experiment parameters on concrete dynamic mechanical performance such as compressive strength, ultimate strain and energy absorption are discussed in details. Additionally, temperature caused a softening effect on the compressive strength of concrete specimens, while CFRP confinement and strain rate play a hardening effect, which can lead to the increase in dynamic compressive strength by 1.8 to 3.6 times compared to static conditions. However, their hardening mechanisms and action stages are extremely different. Finally, nine widely accepted Dynamic Increase Factor (DIF) models considering strain rate effect were summarized, and a simplified model evaluating dynamic compressive strength of post-fire concrete confined by CFRP sheets was proposed, which can provide evidence for engineering emergency repair after fire accidents.
Related Concept Videos
Fiber Reinforced Concrete
Fatigue Strength of Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Frost Resistant Concrete
Introducing microscopic air bubbles into the concrete mix through air entrainment creates small voids that accommodate ice expansion, thereby reducing internal pressures and preventing cracking. The optimal amount of...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...