Related Experiment Video
Updated: Jun 26, 2025

A High-Throughput Multiplexed Screening for Type 1 Diabetes, Celiac Diseases, and COVID-19
Published on: July 5, 2022
Exploring Gluten Assessment in Marketed Products through a Sandwich ELISA Methodology Based on Novel Recombinant
Eduardo Garcia-Calvo1, Aina García-García1, Santiago Rodríguez1
1Department of Nutrition and Food Sciences, School of Veterinary Sciences, Universidad Complutense de Madrid, 28040 Madrid, Spain.
This study presents the development of a sandwich ELISA method for gluten detection in foods, using recombinant Fab antibody fragments against gliadin. The Fabs were chemically biotinylated and immobilized on streptavidin-coated plates as capture antibodies, while alkaline phosphatase-conjugated Fabs were used as detection antibodies. Four different gliadin-binding Fabs were tested and the Fab pair Fab8E-4 and Fab-C showed the best compatibility. An indirect sandwich immunoassay, using unmodified Fab8E-4 for capture and Fab-C as the detection antibody, achieved a detection limit of 26 ng/mL of gliadin, corresponding to 10 mg/kg of gluten in foods. No cross-reactivity was observed against 60 gluten-free species commonly used in the food industry. Analysis of 50 commercial products demonstrated consistent results compared to the standard method for gluten detection. The complete lack of cross-reactivity of the developed immunoassay with oat products potentially provides an advantage over other gluten detection systems.
This study presents the development of a sandwich ELISA method for gluten detection in foods, using recombinant Fab antibody fragments against gliadin. The Fabs were chemically biotinylated and immobilized on streptavidin-coated plates as capture antibodies, while alkaline phosphatase-conjugated Fabs were used as detection antibodies. Four different gliadin-binding Fabs were tested and the Fab pair Fab8E-4 and Fab-C showed the best compatibility. An indirect sandwich immunoassay, using unmodified Fab8E-4 for capture and Fab-C as the detection antibody, achieved a detection limit of 26 ng/mL of gliadin, corresponding to 10 mg/kg of gluten in foods. No cross-reactivity was observed against 60 gluten-free species commonly used in the food industry. Analysis of 50 commercial products demonstrated consistent results compared to the standard method for gluten detection. The complete lack of cross-reactivity of the developed immunoassay with oat products potentially provides an advantage over other gluten detection systems.
More Related Videos
06:50A High-Throughput Electrochemiluminescence 7-Plex Assay Simultaneously Screening for Type 1 Diabetes and Multiple Autoimmune Diseases
Published on: May 29, 2020
13:21Chemically-blocked Antibody Microarray for Multiplexed High-throughput Profiling of Specific Protein Glycosylation in Complex Samples
Published on: May 4, 2012