Total Iodine Quantification and In Vitro Bioavailability Study in Abalone (Haliotis discus hannai) Using Inductively
1Department of Food Science and Biotechnology, Ewha Womans University, 52 Ewhayeodae-gil, Seodaemun-gu, Seoul 03760, Republic of Korea.
Abstract:
The aim of this study is to determine the total iodine content in Korean abalone (Haliotis discus hannai) and to investigate the bioavailability of iodine using an in vitro method. This research paper focuses on total iodine quantification in abalone (Haliotis discus hannai) and its components (viscera and muscle) using inductively coupled plasma mass spectrometry (ICP-MS). Additionally, an in vitro bioavailability study explored iodine absorption potential. Abalone pretreatment involved both the European standard method (ES) and microwave-assisted extraction method (MAE). The limits of detection (LOD) were 0.11 ng/g for both ES and MAE, with a limit of quantification (LOQ) of 5.4 ng/g for MAE. Accuracy, assessed using a reference material (fish muscle, ERM-BB422), showed values of 1.5 ± 0.010 mg/kg for ES and 1.6 ± 0.066 mg/kg for MAE, within an acceptable range of 1.4 ± 0.42 mg/kg. Precision, evaluated using the Horwitz ratio (HorRat) with a reference material, was determined to be 0.45 for ES and 0.27 for MAE. Therefore, total iodine contents were estimated as 74 ± 2.2 µg/g for abalone viscera and 17 ± 0.77 µg/g for abalone muscle with ES, and 76 ± 1.0 µg/g for abalone viscera and 17 ± 0.51 µg/g for abalone muscle with MAE. Recovery tests demonstrated an acceptable range of 90-110%. In the in vitro bioavailability assessment, digestion efficiency yielded ranges of 42-50.2% for viscera and 67-115% for muscle. Absorption efficiency variations were determined as 37-43% for viscera and 48-75% for muscle.
More Related Videos
09:22Absolute Quantitation of Inositol Pyrophosphates by Capillary Electrophoresis Electrospray Ionization Mass Spectrometry
Published on: August 13, 2021
08:21Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences