Performance Assessment for the Validation of Wireless Communication Engines in an Innovative Wearable Monitoring
Alessio Serrani1,2, Andrea Aliverti1
1Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milano, Italy.
Abstract:
In today's health-monitoring applications, there is a growing demand for wireless and wearable acquisition platforms capable of simultaneously gathering multiple bio-signals from multiple body areas. These systems require well-structured software architectures, both to keep different wireless sensing nodes synchronized each other and to flush collected data towards an external gateway. This paper presents a quantitative analysis aimed at validating both the wireless synchronization task (implemented with a custom protocol) and the data transmission task (implemented with the BLE protocol) in a prototype wearable monitoring platform. We evaluated seven frequencies for exchanging synchronization packets (10 Hz, 20 Hz, 30 Hz, 40 Hz, 50 Hz, 60 Hz, 70 Hz) as well as two different BLE configurations (with and without the implementation of a dynamic adaptation of the BLE Connection Interval parameter). Additionally, we tested BLE data transmission performance in five different use case scenarios. As a result, we achieved the optimal performance in the synchronization task (1.18 ticks as median synchronization delay with a Min-Max range of 1.60 ticks and an Interquartile range (IQR) of 0.42 ticks) when exploiting a synchronization frequency of 40 Hz and the dynamic adaptation of the Connection Interval. Moreover, BLE data transmission proved to be significantly more efficient with shorter distances between the communicating nodes, growing worse by 30.5% beyond 8 m. In summary, this study suggests the best-performing network configurations to enhance the synchronization task of the prototype platform under analysis, as well as quantitative details on the best placement of data collectors.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...