Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Motion-robust free-running volumetric cardiovascular MRI
Syed M Arshad1,2, Lee C Potter2,3, Chong Chen1,2
1Biomedical Engineering, The Ohio State University, Columbus, Ohio, USA.
A new method, compressive recovery with outlier rejection (CORe), improves cardiovascular MRI (CMR) by reducing motion artifacts. CORe enhances image quality and flow measurements in free-running scans.
Area of Science:
- Medical Imaging
- Biomedical Engineering
- Cardiovascular Research
Background:
- Free-running volumetric cardiovascular MRI (CMR) is susceptible to motion artifacts.
- Robustness to motion is crucial for accurate CMR image acquisition and analysis.
- Existing methods may not fully address outlier data caused by motion.
Purpose of the Study:
- To introduce and evaluate a novel outlier mitigation technique for free-running volumetric CMR.
- To enhance the robustness of cardiovascular MRI to motion-induced artifacts.
- To improve the reliability of quantitative measurements derived from CMR data.
Main Methods:
- The compressive recovery with outlier rejection (CORe) method models outliers as an additive variable.
- MR physics-guided group sparsity is enforced on the auxiliary variable.
- Joint estimation of the image and auxiliary variable is performed iteratively.
- CORe was compared against traditional compressed sensing (CS), robust regression (RR), and an existing outlier rejection method in simulations and real CMR datasets.
Main Results:
- CORe demonstrated superior performance over CS, RR, and existing methods in simulation studies.
- Expert evaluation confirmed CORe's effectiveness in artifact suppression and maintaining image sharpness for 3D cine CMR.
- CORe provided more reliable and consistent 4D flow measurements, particularly under motion and stress conditions.
Conclusions:
- The presented outlier rejection method, CORe, effectively suppresses motion artifacts in free-running CMR.
- CORe shows significant potential for improving image quality and quantitative analysis across various free-running CMR applications.
- This method enhances the utility of cardiovascular MRI in challenging acquisition scenarios.