Volume measurements of normal orbital structures by computed tomographic analysis
AJR. American Journal of Roentgenology
|July 1, 1985
Summary
This study establishes normal orbital volume ranges using CT scans for bony orbit, soft tissue, fat, and muscle. These measurements provide a baseline for diagnosing conditions like endocrine ophthalmopathy.
Area of Science:
- Ophthalmology
- Radiology
- Anatomy
Background:
- Accurate volumetric measurements of orbital structures are crucial for diagnosing various orbital diseases.
- Previous methods for determining orbital volumes have limitations in precision and in vivo application.
Purpose of the Study:
- To establish normative volumetric data for normal orbital soft tissues, extraocular muscle, orbital fat, and bony orbit in adults.
- To validate the accuracy of computed tomographic (CT) digital data and computer graphic analysis for these measurements.
Main Methods:
- Utilized computed tomographic (CT) digital data and off-line computer graphic analysis.
- Measured volumes of orbital soft tissue, extraocular muscle, orbital fat, and bony orbit in vivo in 29 patients (58 orbits).
- Validated technique accuracy using physical and simulated silicone orbit phantoms (7%-8% accuracy).
Main Results:
- Determined upper limits of normal for adult bony orbit (30.1 cm³), soft tissue (20.0 cm³), orbital fat (14.4 cm³), and muscle (6.5 cm³).
- Observed minor volume differences between sexes but minimal differences between right and left orbits within individuals.
- Established mean values and upper limits for adult orbital structures.
Conclusions:
- The study provides reliable in vivo volumetric data for normal adult orbital structures.
- These normative values serve as a critical reference for future studies and clinical assessments of orbital abnormalities.
- The CT-based method offers an accurate approach for quantifying orbital volumes.