Related Experiment Video
Updated: Jun 20, 2026

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
In-fiber chirped Fabry-Perot cavity for temperature sensing
Abstract:
Measurement resolution and dynamic range of conventional optical fiber sensors are often mutually restricted. In this work, an in-fiber chirped Fabry-Perot cavity (interferometer) is proposed, for the first time to our knowledge, to resolve the conflict between the resolution and dynamic range. The chirped Fabry-Perot interferometer is constructed by two chirped fiber Bragg gratings inscribed in the opposite directions, resulting in a gradually varied (i.e., chirp) cavity length for different reflection wavelengths. As such, the interference spectrum exhibits high figure of merit (FOM) and large free spectrum range (FSR) at long and short wavelength regions, respectively, enabling high-resolution and large-dynamic-range measurement simultaneously. Temperature tests are then carried out to confirm the validity of the solution. The proposed sensing schema may be developed further and find vital applications in biomedicine fields such as endosomatic temperature monitoring of living bodies. The proposed concept of chirped Fabry-Perot interferometer can provide breakout ideas for other sensing scenarios where high-resolution and large-dynamic range are demanded and can be further generalized to other measurands or even free-space interference metrologies.
Related Concept Videos
Thermosensation
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...