Related Experiment Video
Updated: Jul 31, 2026

Amplifying and Quantifying HIV-1 RNA in HIV Infected Individuals with Viral Loads Below the Limit of Detection by Standard Clinical Assays
Published on: September 26, 2011
Monitoring coronavirus disease progression and clinical impact through quantitative viral load testing
Chih-Kai Chang1, Chi-Sheng Chen1, Ming-Jr Jian1
1Division of Clinical Pathology, Department of Pathology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan, Republic of China.
Background:
The viral load (VL) in severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-infected individuals is critical for improving clinical treatment strategies, care, and decisions. Several studies have reported that the initial SARS-CoV-2 VL is associated with disease severity and mortality. Cycle threshold (Ct) values and/or copies/mL are often used to quantify VL. However, a multitude of platforms, primer/probe sets of different SARS-CoV-2 target genes, and reference material manufacturers may cause inconsistent interlaboratory interpretations. The first International Standard for SARS-CoV-2 RNA quantitative assays has allowed diagnostic laboratories to transition SARS-CoV-2 VL results into international units per milliliter (IU/mL). The Cobas SARS-CoV-2 Duo quantitative assay provides VL results expressed in IU/mL.
Materials And Methods:
We enrolled 145 and 50 SARS-CoV-2-positive, hospitalized and 50-negative individuals at the Tri-Service General Hospital, Taiwan from January to May 2022. Each participant's electronic medical record was reviewed to determine asymptomatic, mild, moderate, and severe cases. Nasopharyngeal swabs were collected using universal transport medium. We investigated the association of SARS-CoV-2 VL with disease severity using the Cobas SARS-CoV-2 Duo quantitative assay and its functionality in clinical assessment and decision making to further improve clinical treatment strategies. Limit of detection (LOD) was assessed.
Results:
All 50 SARS-CoV-2-negative samples confirmed negative for SARS-CoV-2, demonstrating 100 % specificity of the Cobas SARS-CoV-2 Duo assay. Patients with severe symptoms had longer hospital stays, and the length of hospital stay (30.56 days on average) positively correlated with the VL (8.22 ± 1.21 log10 IU/mL). Asymptomatic patients had the lowest VL (5.54 ± 2.06 log10 IU/mL) at admission and the shortest hospital stay (14.1 days on average).
Conclusions:
VL is associated with disease severity and duration of hospitalization; therefore, its quantification should be considered when making clinical care decisions and treatment strategies. The Cobas SARS-CoV-2 Duo assay provides a commutable unitage IU/mL for interlaboratory interpretations.
More Related Videos
Related Concept Videos
Investigation of Disease Outbreaks
Genital Herpes