Related Experiment Video
Updated: May 1, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Hybrid extracorporeal cannulation for aortic root pseudoaneurysm re-operation: The role of a multidisciplinary team
Ilaria Franzese1, Florida Gripshi1, Marco Anzini1
1Division of Cardiac Surgery, Cardio-Thoracic and Vascular Department, Azienda Sanitaria Universitaria Giuliano Isontina, Trieste, Italy.
Abstract:
Introduction: Adequate cerebral protection for aortic reoperation is challenging and optimal technique is still controversial.Case Report: We report a hybrid cannulation approach to achieve safe cerebral protection during circulatory arrest to repair an aortic root pseudoaneurysm.Conclusion: A multidisciplinary approach combining conventional techniques and interventional expertise could be considered in complex aortic scenario.
Related Concept Videos
Aneurysm III: Interprofessional Care
Aneurysm IV: Nursing Management