In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
Point-of-care viscoelastic coagulation monitor parameters in Amazon parrots (Amazona spp.)
Amanda Burke1, Miryam Reems1, Maria Spriggs2
1Emergency & Critical Care Department, BluePearl Veterinary Partners, Tampa, Florida, USA.
Objective:
To evaluate the feasibility of the point-of-care viscoelastic coagulation monitor (VCM) in Amazon parrots (Amazona spp.) and describe the parameters with fresh whole-blood samples in healthy Amazon parrots.
Design:
A total of 18 Amazon parrots were enrolled. Physical examinations, a CBC, and a biochemistry profile, including bile acids, were performed on all parrots. VCM tracings were obtained at the time of venipuncture for baseline laboratory work.
Measurements And Main Results:
The median clot time was 2102 seconds (range: 38.6-3599 s), median clot formation time was 929 seconds (range: 21.4-1711 s), median alpha angle was 20 (range: 6-67), and the median maximum clot formation was 8.5 (range: 0-36). The median lysis index at 30 minutes (LI30) was 100 (range: 98-100), and the median lysis index at 45 minutes (LI45) was 100 (range: 90-100). Of 18 samples, alpha angles were not reported in 7 samples, LI30 was not reported in 10 samples, and LI45 was not reported in 12 samples. Of the qualitative curves, 6 reflected normal mammalian curves, and the remainder were consistent with a hypocoaguable state.
Conclusions:
The results were markedly variable, with the majority of VCM tracings being hypocoagulable in comparison with reference intervals established for dogs and cats. Using these protocols, the VCM is not reliable in Amazon parrots. Future areas of investigation include altering the temperature during sample analysis, the use of activators, or an exchange of clotting reagents for an extrinsic pathway activator, which may contribute to the success of this device in avian species.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.