The Clinical and Radiological Outcomes of the Multimodal Use of the Woven EndoBridge Device: A Large Multicenter
Mohamed Nasra1, Davor Pavlin-Premrl2, Sara Protto3
1Department of Medicine, Northern Health, Melbourne, Victoria, Australia.
Background:
The Woven EndoBridge (WEB) is a device used for intrasaccular flow diversion, designed for the elimination of wide-necked bifurcation aneurysms from the circulation. In this study, we aim to assess the safety and efficacy of the WEB and its uses in treating aneurysms of different morphologies and locations.
Methods:
In a retrospective analysis, we compiled a comprehensive dataset from patients treated with the WEB device across three major Australian neurovascular centers from May 2017 to September 2023. The case series encompassed a spectrum of aneurysm types, including wide-necked bifurcation, sidewall, and irregularly shaped aneurysms, as well as cases previously managed with alternative therapeutic strategies. This study additionally encompasses cases where aneurysms were managed using the WEB device in combination with supplementary endovascular devices.
Results:
The study included 169 aneurysms in 161 patients. The rate of satisfactory aneurysm occlusion was 85.6%, with 86.7% of patients maintaining good functional status at their most recent follow-up. The procedure exhibited a low mortality rate of 0.6% and a thromboembolic complication rate of 7.1% (n = 12/161). There were no instances of postoperative re-rupture and the procedure-related hemorrhage rate was low (1.2%, n = 2/169), aligning with the literature regarding the safety and efficacy of the WEB device.
Conclusions:
Our multicenter trial reinforces the WEB device's role as an effective and safe modality for intracranial aneurysm management, supporting its expanded application beyond wide-necked bifurcation aneurysms. Further prospective studies are required to delineate its evolving role fully.
More Related Videos
08:12Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...