Predictive value of fluid balance before extubation on its outcome in mechanically ventilated adults in the intensive care unit
Related Experiment Video
Updated: Jun 26, 2025

Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Zhenzhen Wang1, Wenrui Li2, Chunmei Shui1
1Department of Geriatric Respiratory, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, Chengdu, Sichuan, China.
Background:
Although there are many reasons for extubation failure, maintaining negative or lower positive fluid balances 24 hours before extubation may be a key measure for successful extubation.
Aim:
To assess the predictive value of fluid balance before extubation and its outcome in mechanically ventilated cases in the intensive care unit (ICU).
Study Design:
This retrospective cohort study involved collecting clinical data from patients undergoing mechanical ventilation in Lanzhou general adult ICU from January 2022 to December 2022. Based on extubation outcomes, the patients were divided into a successful extubation group and a failed extubation group. Their fluid balance levels 24 h before extubation were compared with analyse the predictive value of fluid balance on extubation outcomes in patients undergoing mechanical ventilation.
Results:
In this study, clinical data from 545 patients admitted to a general adult ICU were collected. According to the inclusion and exclusion criteria, 265 (48.6%) patients were included, of which 197 (74.3%) were successfully extubated; extubation was unsuccessful in 68 (25.7%) patients. The total intake and fluid balance levels in patients in the failed extubation group 24 h before extubation were significantly higher than those in the successful extubation group, with a median of 2679.00 (2410.44-3193.50) mL versus 2435.40 (1805.04-2957.00) mL, 831.50 (26.25-1407.94) mL versus 346.00 (-163.00-941.50) mL. Receiver operating characteristic (ROC) curve analysis showed that the optimal cut-off value for predicting extubation outcomes was 497.5 mL (sensitivity 64.7%, specificity 59.4%) for fluid balance 24 h before extubation. The area under the ROC curve was 0.627 (95% confidence interval [CI] 0.547-0.707). Based on the logistic regression model, cumulative fluid balance >497.5 mL 24 h before extubation could predict its outcomes in mechanically ventilated patients in the ICU (OR = 5.591, 95% CI [2.402-13.015], p < .05).
Conclusions:
The fluid balance level 24 h before extubation was correlated with the outcome of extubation in mechanically ventilated patients in the ICU. The risk of extubation failure was higher when the fluid balance level was >497.5 mL.
Relevance To Clinical Practice:
Tracheal intubation is a crucial life support technique for many critically ill patients, and determining the appropriate time for extubation remains a challenge for clinicians. Although there are many reasons for extubation failure, acute pulmonary oedema caused by continuous positive fluid balance and volume overload is one of the main reasons for extubation failure. Therefore, it is very important to study the relationship between fluid balance and extubation outcome to improve the prognosis of patients with invasive mechanical ventilation in ICU.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...