Solving the puzzle of 2-hydroxypropyl β-cyclodextrin: Detailed assignment of the substituent distribution by NMR

Eszter Kalydi1, Milo Malanga2, Thorbjørn Terndrup Nielsen3

  • 1Department of Pharmacognosy, Semmelweis University, Üllői út. 26, 1085 Budapest, Hungary.

PubMed

Related Concept Videos

¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR01:15

¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR

The axial and equatorial protons in cyclohexane can be distinguished by performing a variable-temperature NMR experiment. In this process, except for one proton, the remaining eleven protons are replaced by deuterium. The deuterium substitution avoids the possible peak splitting caused by the spin-spin coupling between the adjacent protons. The remaining proton flips between the axial and equatorial positions.
1.1K
¹H NMR: Complex Splitting01:13

¹H NMR: Complex Splitting

A proton M that is coupled to a proton X results in doublet signals for M. However, NMR-active nuclei can be simultaneously coupled to more than one nonequivalent nucleus. When M is coupled to a second proton A, such as in styrene oxide, each peak in the doublet is split into another doublet.
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
1.3K
¹H NMR of Labile Protons: Deuterium (²H) Substitution00:48

¹H NMR of Labile Protons: Deuterium (²H) Substitution

This lesson illustrates the role of deuterium substitution in simplifying the NMR spectrum of compounds comprising labile protons. One method employed is the use of deuterium. Amongst the three isotopes of hydrogen, deuterium (2H) has a nucleus composed of one proton and one neutron. When the D2O solvent is added to a pure dry ethanol solution, its labile proton is substituted with deuterium.
885
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution00:52

¹H NMR of Conformationally Flexible Molecules: Temporal Resolution

At room temperature, the chair conformer of cyclohexane undergoes rapid ring flipping between two equivalent chair conformers at a rate of approximately 105 times per second. These two chair conformers are in equilibrium. The rapid ring flipping results in the interconversion of the axial proton to an equatorial proton and an equatorial to the axial proton. Such interconversions are too rapid and cannot be detected on the NMR timescale. Hence, the NMR spectrometer cannot distinguish between the...
830
¹H NMR Chemical Shift Equivalence: Homotopic and Heterotopic Protons01:03

¹H NMR Chemical Shift Equivalence: Homotopic and Heterotopic Protons

Protons in identical electronic environments within a molecule are chemically equivalent and have the same chemical shift. The replacement test is a useful tool to identify chemical equivalence and predict NMR spectra. A substituent replaces each of the protons being examined and the resulting molecules are compared. If the same molecule is obtained, the protons are equivalent or homotopic. Replacement of any hydrogens in ethane by chlorine yields chloroethane because all six protons are...
2.3K
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)01:19

2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)

Heteronuclear single-quantum correlation spectroscopy (HSQC) is a 2D NMR technique that reveals one-bond correlations between hydrogen and a heteronucleus. The HSQC experiment is similar to the heteronuclear correlation experiment (HETCOR) but is more sensitive. In the HSQC spectrum, the proton chemical shift is plotted on the horizontal F2 axis, while the 13C chemical shift is plotted on the vertical F1 axis. The corresponding proton and 13C spectra are also shown. The HSQC contour plot does...
689