Full state observer-based pole placement controller for pulse width modulation switched mode voltage-controlled buck

Yeshiwas Fetene1, Endalew Ayenew2, Solomon Feleke1

  • 1Electrical and Computer Engineering, Debre Berhan University, Debre Birhan, Ethiopia.

Heliyon
|May 20, 2024
PubMed
Summary

This study introduces a cost-effective controller for switched mode DC-DC converters, removing the need for current sensors. The observer-based design ensures fast response and stable voltage regulation in renewable energy and EV applications.

Related Concept Videos

Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
80
PI Controller: Design01:24

PI Controller: Design

Proportional Integral (PI) controllers are a fundamental component in modern control systems, widely used to enhance performance and mitigate steady-state errors. They are particularly effective in applications such as automatic brightness adjustment on smartphones, where they excel at mitigating steady-state errors for step-function inputs. Unlike PD controllers, which require time-varying errors to function optimally, PI controllers leverage their integral component to address residual...
249
PD Controller: Design01:26

PD Controller: Design

In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
219
Phase-lead and Phase-lag Controllers01:22

Phase-lead and Phase-lag Controllers

Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass...
167
Time and frequency -Domain Interpretation of PI Control01:27

Time and frequency -Domain Interpretation of PI Control

Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
118
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
95