Related Experiment Video
Updated: Jun 26, 2025

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
Published on: April 21, 2023
Unknown appliances detection for non-intrusive load monitoring based on vision transformer with an additional
Qiang Zhao1, Weican Liu2, Keke Li3
1School of Control Engineering, Northeastern University at Qinhuangdao, Hebei, China.
Abstract:
Non-intrusive load monitoring (NILM) offers precise insights into equipment-level energy consumption by analyzing current and voltage data from residential smart meters, thus emerging as a potential strategy for demand-side management in power systems. However, a prevalent limitation in current NILM techniques is the presupposition of a known inventory of household appliances, an assumption that often becomes impractical due to the regular introduction of new appliances by consumers. To address this challenge, our approach integrates a vision transformer network with an additional detection head (ViTD), utilizing V-I trajectory images. Initially, the ViT model is trained to classify known appliances. Subsequently, an additional detection head is incorporated to manipulate the embedded features, encouraging the formation of distinct, compact class centers for the known appliance categories. During testing, samples are identified as either known or unknown appliances based on their proximity to these class centers. We utilize two public datasets, PLAID and WHITED, to demonstrate the effectiveness and superiority of our proposed method.
More Related Videos
Related Concept Videos
Instrument Transformers
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...

