V Dang Luu1, T Xuan Bach1, N Huu An1
1Radiology Center, Bach Mai Hospital, Hanoi, Vietnam.
Background:
AneurysmFlow (Phillips Healthcare) is the flow measurement tool, utilizing an optical flow-based algorithm from DSA, lacks sufficient published studies. This study aimed to assess the significance of flow velocity changes and the Mean Aneurysm Flow Amplitude (MAFA) ratio in evaluating outcomes following flow-diverting treatments.
Methods:
Between June 2021 and October 2022, 41 patients with 42 aneurysms underwent FDS treatment with AneurysmFlow measu-rement at the Bach Mai Radiology Center.
Results:
The tool achieved a 90.5% success rate in 38 out of 42 patients. Most aneurysms (89.5%) were small to medium-sized (<10 mm), and a decrease in flow velocity post-stent deployment was ob-served in 78.9% of cases. Conversely, 21.1% showed increased flow, mainly in aneurysms smaller than 5 mm. No significant association was found between flow changes or MAFA ratio and aneurysm size characteristics. Twenty-two patients (59.5%) underwent re-examination at 6 months, revealing no correlation in MAFA ratio between completely and incompletely occluded aneurysms.
Conclusions:
Our current investigation, primarily centered on small and medium-sized aneurysms, did not uncover any link between quantitative flow changes assessed using the AneurysmFlow software and the occlusion status of aneurysms at the 6-month follow-up post-flow diverter treatment. Larger case series with extended follow-up imaging are necessary to further explore these findings.
More Related Videos
12:00Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
11:16In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
Related Concept Videos
Blood Flow
Steady Flow of a Fluid Stream
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
Pipe Flowrate Measurement
The orifice meter is a simple,...
General External Flow Characteristics
Rapidly Varying Flow
Applications of Integration to Find Blood Flow