Related Experiment Video
Updated: Jun 25, 2025

Effects of Surgical Masks on Cardiopulmonary Function in Healthy Subjects
Published on: February 12, 2021
Effects of Obesity and Sex on Ventilatory Constraints during a Cardiopulmonary Exercise Test in Children
Dharini M Bhammar1, Celia W Nusekabel1, Daniel P Wilhite
1Center for Tobacco Research, Division of Medical Oncology, Department of Internal Medicine, The Ohio State University, Columbus, OH.
Purpose:
Ventilatory constraints are common during exercise in children, but the effects of obesity and sex are unclear. The purpose of this study was to investigate the effects of obesity and sex on ventilatory constraints (i.e., expiratory flow limitation (EFL) and dynamic hyperinflation) during a maximal exercise test in children.
Methods:
Thirty-four 8- to 12-yr-old children without obesity (18 females) and 54 with obesity (23 females) completed pulmonary function testing and maximal cardiopulmonary exercise tests. EFL was calculated as the overlap between tidal flow-volume loops during exercise and maximal expiratory flow-volume loops. Dynamic hyperinflation was calculated as the change in inspiratory capacity from rest to exercise.
Results:
Maximal minute ventilation was not different between children with and without obesity. Average end-inspiratory lung volumes (EILV) and end-expiratory lung volumes (EELV) were significantly lower during exercise in children with obesity (EILV: 68.8% ± 0.7% TLC; EELV: 41.2% ± 0.5% TLC) compared with children without obesity (EILV: 73.7% ± 0.8% TLC; EELV: 44.8% ± 0.6% TLC; P < 0.001). Throughout exercise, children with obesity experienced more EFL and dynamic hyperinflation compared with those without obesity ( P < 0.001). Also, males experienced more EFL and dynamic hyperinflation throughout exercise compared with females ( P < 0.001). At maximal exercise, the prevalence of EFL was similar in males with and without obesity; however, the prevalence of EFL in females was significantly different, with 57% of females with obesity experiencing EFL compared with 17% of females without obesity ( P < 0.05). At maximal exercise, 44% of children with obesity experienced dynamic hyperinflation compared with 12% of children without obesity ( P = 0.002).
Conclusions:
Obesity in children increases the risk of developing mechanical ventilatory constraints such as dynamic hyperinflation and EFL. Sex differences were apparent with males experiencing more ventilatory constraints compared with females.
More Related Videos
08:30Intraperitoneal Glucose Tolerance Test, Measurement of Lung Function, and Fixation of the Lung to Study the Impact of Obesity and Impaired Metabolism on Pulmonary Outcomes
Published on: March 15, 2018
09:36Assessment of Child Anthropometry in a Large Epidemiologic Study
Published on: February 2, 2017
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Factors Affecting Respiration
Respiratory Volumes and Capacities I
Respiratory Volumes and Capacities