Related Experiment Video
Updated: Jun 25, 2025

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
The exploration of a compound cone-beam CT contrast agent for diagnosis of human extracted cracked tooth
Ziyang Hu1,2, Yanni Hu1, Shi Xu3
1Department of Dentomaxillofacial Radiology, Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China.
Objectives:
This study aims to investigate the use of sodium iodide (NaI), dimethyl sulfoxide (DMSO), ethyl alcohol, and ethyl acetate as cone-beam CT (CBCT) contrast agents for diagnosing cracked teeth. The optimal delay time for detecting the number of crack lines beyond the dentino-enamel junction (Nd), the number of cracks extending from the occlusal surface to the pulp cavity (Np), and the depth of the crack lines was explored.
Methods:
14 human extracted cracked teeth were collected, 12 were used for enhanced scanning, and 2 were used for exploring the characteristic of crack lines. The teeth were scanned in 3 CBCT enhanced scanning (ES) modes: ES1 using meglumine diatrizoate (MD); ES2 using NaI and DMSO, ES3 using NaI, DMSO, ethyl alcohol and ethyl acetate. Three delay times (15mins, 30mins, and 60mins) were set for scanning. Nd, Np, and depth of crack lines were evaluated.
Results:
There were totally 24 crack lines on 12 cracked teeth. Nd was 10 in ES1 at 60mins, 24 in ES2 at 60mins and 24 in ES3 at 15mins. Np was 1 in ES1 at 60mins, 10 in ES2 at 60mins and 21 in ES3 at 60mins, and there were significantly different among them (p < 0.01). The average depth presented on ES3 was significantly deeper than ES1 and ES2 (p < 0.01).
Conclusion:
NaI, DMSO, ethyl alcohol and ethyl acetate show potential as contrast agents for enhanced CBCT scanning in diagnosis of cracked teeth and their depth in vivo. A delay time of 15 min is necessary to confirm the existence of crack lines, while a longer delay time is required to ascertain if these crack lines extend to the pulp cavity.
More Related Videos
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
13:16Computed Tomography and Optical Imaging of Osteogenesis-angiogenesis Coupling to Assess Integration of Cranial Bone Autografts and Allografts
Published on: December 22, 2015
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT