Related Experiment Video
Updated: Jun 25, 2025

Experimental and Imaging Techniques for Examining Fibrin Clot Structures in Normal and Diseased States
Published on: April 1, 2015
Comparison of coagulation and fibrinolysis in Irish Wolfhounds and age-matched control dogs using tissue plasminogen
Samantha Davis1, Daniel J Fletcher1, Ashley Newman2
1Department of Clinical Sciences, Cornell University College of Veterinary Medicine, Ithaca, New York, USA.
Objective:
To determine if Irish Wolfhounds (IWs), like other sighthounds, are hyperfibrinolytic compared with nonsighthound dogs using 2 native and tissue plasminogen activator (tPA)-enhanced viscoelastic assays, one that is whole blood-based (viscoelastic coagulation monitor [VCM]) and the other that is plasma-based thromboelastography (TEG).
Design:
Cohort study.
Setting:
University teaching hospital.
Animals:
A convenience sample of 27 IWs recruited from the Irish Wolfhound Association of New England Specialty and the local community, and 27 healthy, age-matched, large-breed control dogs.
Interventions:
None.
Measurements And Main Results:
Blood samples including CBC, biochemistry, traditional coagulation, and viscoelastic testing were collected from IWs and control dogs. Twelve IWs had viscoelastic testing. IWs had lower fibrinogen concentrations (215.5 ± 57.8 vs 251.4 ± 64.5 mg/dL, P = 0.034) and formed weaker clots on both whole-blood VCM and plasma TEG assays (maximum clot firmness [VCM-MCF] = 39.4 [25.1-48.8] vs 48.5 [34.6-57.3], P = 0.0042; maximum amplitude [TEG-MA] = 22.7 [14.7-33.6] vs 32.2 [26.9-42.0], P < 0.0001). IWs were hyperfibrinolytic compared with control dogs on VCM whole-blood assays, with 25 U/mL tPA (lysis at 30 min [VCM-LI30] = 68.1 [0-100] vs\ 99.9 [63.3-100], P = 0.0009; lysis at 45 min [VCM-LI45] = 31.0 [0-100] vs 98.1 [38.4-100], P = 0.0002) but hypofibrinolytic compared with controls on TEG plasma assays with 50 U/mL tPA (lysis at 30 min [TEG-LY30] = 45.7 [4.6-94.6] vs 93.7 [12.3-96.5], P = 0.0004; lysis at 60 min [TEG-LY60] = 68.7 [29.7-96.8] vs 95.7 [34.4-97.6], P = 0.0003). Minimal fibrinolysis was measured on whole-blood VCM or plasma TEG assays without the addition of tPA, and there were no differences between the 2 groups.
Conclusions:
Weaker clots were found in IWs than control dogs. With the addition of tPA, IWs had evidence of hyperfibrinolysis on whole-blood VCM assays and hypofibrinolysis on plasma TEG assays compared with control dogs. Without the addition of tPA, however, both groups of dogs showed minimal fibrinolysis on viscoelastic testing.