Related Experiment Video
Updated: Jun 25, 2025

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
A long-standing conundrum: an unusual case of 2:1 atrioventricular block with conflicting findings
Hakan Gökalp Uzun1, Selim Ekinci2
1Department of Cardiology, University of Health Sciences, Tepecik Training and Research Hospital, Izmir, Turkey. gokalpuzun@icloud.com.
Abstract:
A 2:1 atrioventricular (AV) block can occur anywhere within the conduction system, and noninvasive measurements may not always predict the exact site of the block. Although localization of the block is critical for deciding any treatment, patients should also be carefully questioned about symptoms both at rest and during exertion. A case of 2:1 AV block that was symptomatic only during exertion, appeared infranodal by noninvasive diagnostic methods, but was found to be intranodal on electrophysiological study is reported.