Related Experiment Video
Updated: Jun 25, 2025

Open-source Toolkit: Benchtop Carbon Fiber Microelectrode Array for Nerve Recording
Published on: October 29, 2021
Cost of sterility: probe covers should not be mandated for single-shot peripheral nerve blocks
Philipp Gerner1, Veena Graff2, Melody Herman3
1Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts, USA pgerner1@mgh.harvard.edu.
Abstract:
Ultrasound guidance has become ubiquitous with regional anesthesia, but little consistency exists on necessary ultrasound probe hygiene and sterility barriers. Fear of possible infection has led to calls for universal use of sterile ultrasound probe covers. Available data seems to suggest that single-shot peripheral nerve blocks have a low infectious risk. The widespread use of single-use disposable probe covers would carry an associated cost, increased environmental impact, and little evidence to suggest that they are effective at preventing infection if proper technique is used. While various parties have labeled single-shot nerve blocks as a sterile procedure, in practice, it is a clean technique. In this article, we argue that mandating the use of probe covers is unnecessary and that it should be left to the anesthesiologist to determine what type of anti-infection equipment is necessary for single-shot nerve blocks based on their practice situation and expertize.
Related Concept Videos
Local Anesthetics: Differential Sensitivity of Nerve Fibers
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...