Indirect assessment of low-intensity shockwave therapy's energy density and pulse frequency for erectile dysfunction:
David E Hinojosa-Gonzalez1,2, Alejandro Talamas Mendoza3, Mauricio Torres-Martinez3
1Tecnologico de Monterrey, Escuela de Medicina y Ciencias de la Salud, Ave Morones Prieto 3000, Monterrey, NL, 64000, Mexico. David.Hinojosa-Gonzalez@bcm.edu.
Abstract:
Shockwaves are thought to activate regenerative and angiogenic pathways, providing a possible therapeutic benefit for patients with erectile dysfunction. This study aimed to analyze the effectiveness of low-intensity extracorporeal shockwave therapy energy density and pulse frequency. In May 2022, a systematic search of online databases was performed to identify randomized clinical trials related to low-intensity extracorporeal shockwave therapy in erectile dysfunction. Eligible articles compared low-intensity extracorporeal shockwave therapy to controls or sham procedures. A Bayesian framework with 200,000 Markov chains was performed. We included a total of 1272 patients from 18 studies. The energy flux density measured in joules included 0.09 mJ/mm2 (mean difference 3.2 IIEF [95% CrI 2.8, 3.6]), 0.15 mJ/mm2 (mean difference 4.9 IIEF [95% CrI 2.8, 7.2]) and 0.20 mJ/mm2 (mean difference 1.2 IIEF [95% CrI 0.11, 2.3]). Of these, 0.15 mJ/mm2 had the greatest ranking (SUCRA = 0.983) compared with placebo. When analyzed by pulse frequency, significant increases were found in 500 pulses/session (mean difference 2.5 IIEF [CrI 1.9, 3.2]), 1500 pulses/session (mean difference 4.6 IIEF [95% CrI 3.9, 5.4]) and > 3000 pulses/session (mean difference 3.1 IIEF [95% CrI 2.1, 4.2]). Of these, 1500 pulses/session had the highest SUCRA, at 0.996. Our network meta-analysis suggests that low-intensity extracorporeal shockwave therapy is an effective intervention for erectile dysfunction, as measured by increases in the IIEF-EF. Sessions featuring 1500 pulses and an energy flux density of 0.15 mJ/mm2 appear to be the most effective.
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Male Sexual Response: Erection & Ejaculation
The blood filling the erectile tissues compresses the veins, which helps to prevent blood from leaving...
Special considerations while measuring pulse