99m Tc-DTPA dynamic SPECT/CT renogram in adults: feasibility and diagnostic benefit
Maria Spiliotopoulou1, Nikolaos Papathanasiou1, Łukasz Łabieniec2
1Department of Nuclear Medicine, University Hospital of Patras, University of Patras, Medical School, Patras, Greece and .
Objective:
The objective of this study is to investigate the feasibility and potential advantages of 99m Tc-DTPA dynamic single photon emission computed tomography/computed tomography (SPECT/CT) renogram in adults.
Methods:
Fifty-five patients aged 19-80 years (mean 56.3) were enrolled. The imaging protocol included: day 1: 99m Tc-DTPA planar renogram, followed by planar 99m Tc-DMSA scan. Day 3: attenuation-corrected dynamic 99m Tc-DTPA SPECT renogram [DSPECT(AC)] and Cr-51 ethylenediamine tetraacetic acid (EDTA) glomerular filtration rate (GFR) calculation. DSPECT(AC) included an initial CT scan followed by 12 consecutive SPECT sessions acquired via continuous-mode acquisition for a total of 24 min. Fast SPECT sequences (1-2 s/projection, 60 projections, every 6°) were obtained for the first 8 min, followed by slower acquisitions (3-4 s/projection) during the rest of the study. Renal activity was measured in the total kidney volume by regions of interest drawn on consecutive transaxial slices of the third SPECT, which were then copied on the whole 12-SPECT series. Corresponding time-activity curves were created. DSPECT(AC) parameters were compared with those of planar renogram. The reference method for split renal function was 99m Tc-DMSA (geometrical mean of anterior and posterior projection counts) and for GFR the Cr-51 EDTA 2-blood sample clearance method.
Results:
DSPECT(AC) images were of good quality. There was good correlation between renogram parameters (time to peak activity and NORA20) comparing the two techniques ( r = 0.959 and 0.933, respectively). In 21 cases with >30% absolute difference between the two kidneys, spilt renal function calculation by DSPECT(AC) correlated perfectly ( r = 0.968) with the reference method, whereas planar renogram was less accurate ( r = 0.843). Anatomic information provided by nonenhanced CT offered an integrated structural-functional view valuable for final diagnosis. DSPECT(AC) early kidney uptake as a fraction of injected dose correlated better with reference GFR ( r = 0.789) than the Gates' method ( r = 0.642).
Conclusion:
99m Tc-DTPA dynamic SPECT/CT renogram is feasible with conventional SPECT/CT systems. It allows accurate split renal function measurement, offers additional anatomical information and can be used for closer approximation of GFR compared with Gates' method.
More Related Videos
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...