Related Experiment Video
Updated: Jun 25, 2025

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
A finite element analysis of periodontal ligament fluid mechanics response to occlusal loading based on
Zhongyu Wang1, Sa Du1, Huilin Zhu1
1Second Clinical Division, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology & NHC Key Laboratory of Digital Stomatology & NMPA Key Laboratory for Dental Materials, No.22, Zhongguancun South Avenue, Haidian District, Beijing.
Objective:
Considering fluid stimulation is one of the essential biomechanical signals for periodontal tissues, this study aims to characterizing fluid mechanics response during occlusal loading by a hydro-mechanical coupling model for periodontal ligament.
Design:
Models simulating periodontium with normal bone height and with intraosseous defects were built with three mechanical modules: tooth, periodontal ligament and alveolar bone. Tooth was modeled as linear elastic, and periodontal ligament and alveolar bone as a hydro-mechanical coupling model. Transient analyses under dynamic occlusal loading were performed. Fluid dynamics within periodontal ligament space was simulated and visualized by post-processing module.
Results:
Reciprocating oscillatory flow occurred within the periodontal ligament under occlusal loading. Higher pore pressure and fluid velocity were observed in furcation and apical regions compared to mid-root and cervical regions. Intraosseous defects increased pore pressure and fluid velocity within the periodontal ligament, most significantly near the defect.
Conclusion:
Based on the results of the hydro-mechanical coupling model, significant oscillatory fluid motion is observed within the periodontal ligament under occlusal loading. Particularly, higher fluid velocity is evident in the furcation and apical areas. Additionally, Intraosseous defects significantly enhance fluid motion within the periodontal ligament.
Related Concept Videos
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Generalized Hooke's Law
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to...