Related Experiment Video
Updated: Jun 25, 2025

Adjunctive Diode Laser Therapy and Probiotic Lactobacillus Therapy in the Treatment of Periodontitis and Peri-Implant Disease
Published on: May 9, 2022
Comparative Evaluation of Er: YAG Laser, Diode Laser, and Novamin Technology for Dentinal Tubule Occlusion: An
Vivek Srivastava1, Shreya Haldar1, Vipul Srivastava2
1Department of Periodontology, Sardar Patel Post Graduate Institute of Dental and Medical Sciences, Lucknow, IND.
Background:
Dentinal hypersensitivity is a brief and painful oral condition that is characterized by an abrupt shooting sensation. Stimulation occurs when hot, cold, sweet, or sour food comes into contact with exposed dentinal tubules. The present study used a scanning electron microscope (SEM) and energy dispersive X-ray analysis (EDX) to investigate the efficacy of Er: YAG, 810 nm diode LASER, and NovaMin Technology in obstructing dentinal tubules.
Material And Methods:
We extracted the outer layers of 30 human teeth to expose the tubules and then treated the surfaces with 17% ethylenediaminetetraacetic acid (EDTA) to create an etched effect. Three cohorts were created from the portions. Group A was subjected to the application of Erbium:Yttrium-Aluminum-Garnet (Er: YAG) laser with a power output of 2W in the non-contact mode for 1 minute. Group B was subjected to the application of an 810nm diode laser with a power output of 1W in continuous mode for 30 seconds. Group C was subjected to the application of NovaMin paste, which contains a 927 ppm fluoride content. Following the therapy, occluded dentinal tubules were analyzed using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) for both quantitative and qualitative examination. The data analysis was conducted using a one-way analysis of variance (ANOVA) and Tukey's test, with a significance threshold of 0.05.
Results:
The average percentages of complete blockage of dentinal tubules in Groups A, B, and C were evaluated using the number of entirely unobstructed dentinal tubules at magnifications of 2000X (F = 3.05, p = 0.064), 5000X (F = 5.33, p = 0.011), and 10000X (F = 8.63, p = 0.001). The count of partially open dentinal tubules seen at magnifications of 2000X, 5000X, and 10000X was F = 10.15 (P < 0.001), F = 5.97 (p = 0.007), and F = 2.12 (p = 0.140) accordingly.
Conclusion:
NovaMin technology has demonstrated more effectiveness in blocking dentinal tubules compared to 810nm diodes and Er: YAG lasers.
More Related Videos
06:23Development of a Noninvasive, Laser-Assisted Experimental Model of Corneal Endothelial Cell Loss
Published on: April 24, 2020
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024