Related Experiment Video
Updated: Jun 25, 2025

Quantitative Visualization and Detection of Skin Cancer Using Dynamic Thermal Imaging
Published on: May 5, 2011
Review of the Capacity to Accurately Detect the Temperature of Human Skin Tissue Using the Microwave Radiation Method
1School of Information Science and Engineering, Southeast University, Nanjing 210096, China.
Abstract:
Microwave radiometry (MWR) is instrumental in detecting thermal variations in skin tissue before anatomical changes occur, proving particularly beneficial in the early diagnosis of cancer and inflammation. This study concisely traces the evolution of microwave radiometers within the medical sector. By analyzing a plethora of pertinent studies and contrasting their strengths, weaknesses, and performance metrics, this research identifies the primary factors limiting temperature measurement accuracy. The review establishes the critical technologies necessary to overcome these limitations, examines the current state and prospective advancements of each technology, and proposes comprehensive implementation strategies. The discussion elucidates that the precise measurement of human surface and subcutaneous tissue temperatures using an MWR system is a complex challenge, necessitating an integration of antenna directionality for temperature measurement, radiometer error correction, hardware configuration, and the calibration and precision of a multilayer tissue forward and inversion method. This study delves into the pivotal technologies for non-invasive human tissue temperature monitoring in the microwave frequency range, offering an effective approach for the precise assessment of human epidermal and subcutaneous temperatures, and develops a non-contact microwave protocol for gauging subcutaneous tissue temperature distribution. It is anticipated that mass-produced measurement systems will deliver substantial economic and societal benefits.
More Related Videos
08:52Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
08:50Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management
Published on: September 2, 2015
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Absorption of Radiation