Related Experiment Video
Updated: Jul 20, 2026

Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
Published on: April 13, 2013
Mask-aware transformer with structure invariant loss for CT translation
Wenting Chen1, Wei Zhao2, Zhen Chen1
1Department of Electrical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region of China.
This study introduces a Mask-Aware Transformer (MAFormer) for translating plain CT scans to multi-phase enhanced computed tomography (MPECT) images. The novel method leverages clinical domain knowledge to improve liver lesion detection and patient safety.
Area of Science:
- Medical Imaging
- Artificial Intelligence
Background:
- Multi-phase enhanced computed tomography (MPECT) is crucial for liver lesion detection but carries allergy risks.
- Current CT translation methods overlook valuable clinical domain knowledge, limiting their effectiveness.
Purpose of the Study:
- To develop an automatic CT translation method that incorporates clinical domain knowledge for improved MPECT image generation.
- To enhance liver lesion detection and reduce patient allergy risks associated with MPECT examinations.
Main Methods:
- Proposed a Mask-Aware Transformer (MAFormer) model for CT translation.
- Introduced a mask estimator to predict subtraction images, highlighting contrast-enhanced regions.
- Developed Mask-Aware Transformer based Normalization (MATNorm) for integrating subtraction images and capturing dependencies.
- Implemented a structure invariant loss to preserve biological structures in translated CT images.
Main Results:
- The MAFormer model effectively translates plain CT to MPECT images.
- The method demonstrates superiority over existing state-of-the-art CT translation techniques.
- Experimental results validate the effectiveness of incorporating clinical domain knowledge.
Conclusions:
- The MAFormer represents a significant advancement in automatic CT translation for medical imaging.
- This approach holds promise for improving diagnostic accuracy and patient safety in liver disease diagnosis.
Related Concept Videos
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the copper windings...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The winding...
Transformers with Off-Nominal Turns Ratios
Per-Unit Sequence Models
Zero-sequence currents, which are identical in magnitude and phase, generate a neutral current, resulting in voltage drops across the neutral impedance and the low-voltage winding. If the...

