Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Chromatographic Methods: Terminology01:18

Chromatographic Methods: Terminology

2.1K
Chromatography is an analytical technique widely used in fields such as chemistry, biology, environmental science, and pharmaceuticals to separate the components of a mixture and identify substances between them. The process of chromatography is based on the interactions between two distinct phases: the stationary phase and the mobile phase. The stationary phase is fixed in place by a supporting material, while the mobile phase moves over it, carrying the solutes. As the mobile phase travels,...
2.1K
Optimizing Chromatographic Separations01:15

Optimizing Chromatographic Separations

387
Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
387
Silica Gel Column Chromatography: Overview01:10

Silica Gel Column Chromatography: Overview

1.2K
Silica gel column chromatography is a technique for separating compounds using a column packed with silica gel as the stationary phase. This method relies on differences in the polarity of compounds. Based on their polarities, compounds move between the stationary phase (silica gel) and the mobile phase (the solvent), forming discrete bands in the column.
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
1.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Uncertainty-driven model-based search methods for method development in liquid chromatography.

Journal of chromatography. A·2026
Same author

Automated micropillar array design with Bayesian optimization and computational fluid dynamics.

Journal of chromatography. A·2026
Same author

Computational study of the mass transfer effects in metal-organic framework columns for liquid chromatography.

Journal of chromatography. A·2026
Same author

Revisiting the definition and measurement of total accessible and hold-up volumes in liquid chromatography: Current understanding and advances.

Journal of chromatography. A·2026
Same author

SERS Substrate Fabrication via Rapid Triboelectrification-Driven Self-Assembly of Close-Packed Colloidal Monolayers.

Small methods·2026
Same author

Kinetic plot method for the optimal column and instrument design for high speed chiral SFC applications.

Journal of chromatography. A·2026
Same journal

Stereo-sensitive modelling of gas chromatographic retention indices of mono-cycloalkanes in jet fuel range.

Journal of chromatography. A·2026
Same journal

Approaches to using retention indices with coupled column pressure tuning in gas chromatography.

Journal of chromatography. A·2026
Same journal

MOF-supported surface-imprinted polymer for hazard governance of aristolochic acids in herbal matrices: A safety-control strategy supported by multiscale simulations.

Journal of chromatography. A·2026
Same journal

Portable cold-assisted head-space solid-phase microextraction coupled with GC-MS/MS for sensitive determination of trace polychlorinated naphthalenes in water.

Journal of chromatography. A·2026
Same journal

Characterization of phosphorous impurities originating from the synthesis of Sarin.

Journal of chromatography. A·2026
Same journal

Extraction and chromatographic purification of purpurin: A scalable approach using modified dry column vacuum chromatography.

Journal of chromatography. A·2026
See all related articles

Related Experiment Video

Updated: Jun 25, 2025

Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
08:56

Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry

Published on: November 22, 2024

611

A new chromatographic response function with automatically adapting weight factor for automated method development.

Leon E Niezen1, Gert Desmet1

  • 1Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, Brussel 1050, Belgium.

Journal of Chromatography. A
|May 24, 2024
PubMed
Summary
This summary is machine-generated.

A new self-adaptive chromatographic response function (CRF) was developed for automated method development. This novel CRF flawlessly optimizes separation quality and speed, overcoming limitations of existing methods.

Keywords:
Automated method developmentChromatogram simulationChromatographic response function (CRF)

More Related Videos

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
14:42

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Published on: September 23, 2021

4.8K
Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
10:14

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography

Published on: September 2, 2020

5.0K

Related Experiment Videos

Last Updated: Jun 25, 2025

Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
08:56

Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry

Published on: November 22, 2024

611
Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
14:42

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Published on: September 23, 2021

4.8K
Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
10:14

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography

Published on: September 2, 2020

5.0K

Area of Science:

  • Analytical Chemistry
  • Chromatography
  • Method Development

Background:

  • Automated method development in chromatography relies on objective functions like chromatographic response functions (CRFs).
  • Existing CRFs often exhibit issues like multiple optima and sensitivity to weighting factors, hindering optimal separation.
  • These limitations impact the balance between separation quality (resolution) and analysis time.

Purpose of the Study:

  • To introduce a novel chromatographic response function (CRF) with self-adaptive weighting.
  • To evaluate the performance of the new CRF against established CRFs for automated gradient optimization.
  • To demonstrate improved accuracy and reliability in identifying optimal chromatographic conditions.

Main Methods:

  • Development of a new CRF incorporating a self-adaptive time penalty term.
  • In silico testing using 100 randomly generated samples.
  • Comparative analysis of the new CRF against frequently used literature CRFs.
  • Evaluation considering spectral peak shape data.

Main Results:

  • The proposed self-adaptive CRF achieved 100% success in identifying optimal gradient parameters.
  • Existing CRFs were inaccurate for 50-60% of the tested samples.
  • The new CRF consistently provided the best resolution in the shortest possible time.

Conclusions:

  • The novel self-adaptive CRF significantly outperforms traditional CRFs in automated chromatographic method development.
  • This advancement offers a robust solution for optimizing separation quality and speed.
  • Further minor modifications to the CRF are proposed for discussion.