Related Experiment Video
Updated: Jun 19, 2026

Intraductal Injection of LPS as a Mouse Model of Mastitis: Signaling Visualized via an NF-κB Reporter Transgenic
Published on: September 4, 2012
Validity of luminometry and bacteriological tests for diagnosing intramammary infection at dry-off in dairy cows
J Denis-Robichaud1, N Barbeau-Grégoire2, M-L Gauthier3
1Independent researcher, Amqui, Québec, Canada G5J 2N5.
Abstract:
The objective of this cross-sectional study was to estimate the validity of laboratory culture, Petrifilm and Tri-Plate on-farm culture systems, as well as luminometry to correctly identify IMI at dry-off in dairy cows, considering all tests to be imperfect. From September 2020 until December 2021, we collected composite milk samples from cows before dry-off and divided them into 4 aliquots for luminometry, Petrifilm (aerobic count), Tri-Plate, and laboratory culture tests. We assessed multiple thresholds of relative light units (RLU) for luminometry, and we used thresholds of ≥100 cfu/mL for the laboratory culture, ≥50 cfu/mL for Petrifilm, and ≥1 cfu for Tri-Plate tests. We fitted Bayesian latent class analysis models to estimate the sensitivity (Se) and specificity (Sp) for each test to identify IMI, with 95% credibility interval (BCI). Using different prevalence measures (0.30, 0.50, and 0.70), we calculated the predictive values (PV) and misclassification cost terms (MCT) at different false negative-to-false-positive ratios (FN:FP). A total of 333 cows were enrolled in the study from one commercial Holstein herd. The validity of the luminometry was poor for all thresholds, with an Se of 0.51 (95% BCI = 0.43-0.59) and Sp of 0.38 (95% BCI = 0.26-0.50) when using a threshold of ≥150 RLU. The laboratory culture had an Se of 0.93 (95% BCI = 0.85-0.98) and Sp of 0.69 (95% BCI = 0.49-0.89); the Petrifilm had an Se of 0.91 (95% BCI = 0.80-0.98) and Sp of 0.71 (95% BCI = 0.51-0.90); and the Tri-Plate had an Se of 0.65 (95% BCI = 0.53-0.82) and Sp of 0.85 (95% BCI = 0.66-0.97). Bacteriological tests had good PV, with comparable positive PV for all 3 tests, but lower negative PV for the Tri-Plate compared with the laboratory culture and the Petrifilm. For a prevalence of IMI of 0.30, all 3 tests had similar MCT, but for prevalence of 0.50 and 0.70, the Tri-Plate had higher MCT in scenarios where leaving a cow with IMI untreated is considered to have greater detrimental effects than treating a healthy cow (i.e., FN:FP of 3:1). Our results showed that the bacteriological tests have adequate validity to diagnose IMI at dry-off, but luminometry does not. We concluded that although luminometry is not useful to identify IMI at dry-off, the Petrifilm and Tri-Plate tests performed similarly to laboratory culture, depending on the prevalence and importance of the FP and FN results.
Related Concept Videos
Pneumonia III: Complications and Assessment
Pulmonary Tuberculosis IV
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Serum Laboratory Studies, Stool Test, Breath Test
Urine Studies II: Urine Culture and Sensitivity Test
Automated Microbial Diagnostics

