Related Experiment Video
Updated: Jun 25, 2025

Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Central venous oxygen saturation changes as a reliable predictor of the change of CI in septic shock: To explore
Purpose:
Assessing fluid responsiveness relying on central venous oxygen saturation (ScvO2) yields varied outcomes across several studies. This study aimed to determine the ability of the change in ScvO2 (ΔScvO2) to detect fluid responsiveness in ventilated septic shock patients and potential influencing factors.
Methods:
In this prospective, single-center study, all patients conducted from February 2023 to January 2024 received fluid challenge. Oxygen consumption was measured by indirect calorimetry, and fluid responsiveness was defined as an increase in cardiac index (CI) ≥ 10% measured by transthoracic echocardiography. Multivariate linear regression analysis was conducted to evaluate the impact of oxygen consumption, arterial oxygen saturation, CI, and hemoglobin on ScvO2 and its change before and after fluid challenge. The Shapiro-Wilk test was used for the normality of continuous data. Data comparison between fluid responders and non-responders was conducted using a two-tailed Student t-test, Mann Whitney U test, and Chi-square test. Paired t-tests were used for normally distributed data, while the Wilcoxon signed-rank test was used for skewed data, to compare data before and after fluid challenge.
Results:
Among 49 patients (31 men, aged (59 ± 18) years), 27 were responders. The patients had an acute physiology and chronic health evaluation II score of 24 ± 8, a sequential organ failure assessment score of 11 ± 4, and a blood lactate level of (3.2 ± 3.1) mmol/L at enrollment. After the fluid challenge, the ΔScvO2 (mmHg) in the responders was greater than that in the non-responders (4 ± 6 vs. 1 ± 3, p = 0.019). Multivariate linear regression analysis suggested that CI was the only independent influencing factor of ScvO2, with R2 = 0.063, p = 0.008. After the fluid challenge, the change in CI became the only contributing factor to ΔScvO2 (R2 = 0.245, p < 0.001). ΔScvO2 had a good discriminatory ability for the responders and non-responders with a threshold of 4.4% (area under the curve = 0.732, p = 0.006).
Conclusion:
ΔScvO2 served as a reliable surrogate marker for ΔCI and could be utilized to assess fluid responsiveness, given that the change in CI was the sole contributing factor to the ΔScvO2. In stable hemoglobin conditions, the absolute value of ScvO2 could serve as a monitoring indicator for adequate oxygen delivery independent of oxygen consumption.
More Related Videos
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...