Related Experiment Video
Updated: Jun 25, 2025

Construction of a Low-cost Mobile Incubator for Field and Laboratory Use
Published on: March 19, 2019
Identifying and Responding to Lead in Drinking Water in a University Setting
Audrey G Bousquet1, Lauren A Eaves1,2, Kim Haley3
1Department of Environmental Sciences and Engineering, Gillings School of Global Public Health, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
None:
Lead is an established neurotoxicant, and it has known associations with adverse neurodevelopmental and reproductive outcomes. Exposure to lead at any level is unsafe, and the United States (US) has enacted various federal and state legislations to regulate lead levels in drinking water in K-12 schools and childcare facilities; however, no regulations exist for higher education settings. Upon the discovery of lead in drinking water fixtures in the University of North Carolina at Chapel Hill (UNC-CH) campus, a cross-campus water testing network and sampling plan was developed and deployed. The campaign was based on the US Environmental Protection Agency's (EPA) 3Ts (Training, Testing, and Taking Action) guidance. The seven-month campaign involved 5954 tests on 3825 drinking water fixtures across 265 buildings. A total of 502 (8.43%) tests showed lead above the limit of detection (1 part per billion, ppb), which represented 422 (11.03%) fixtures. Fewer than 1.5% of the tests were above the EPA action level for public water systems (15 ppb). In conclusion, systematic testing of all the fixtures across campus was required to identify localized contamination, and each entity in the cross-campus network undertook necessary roles to generate a successful testing campaign. UNC-CH established preventative measures to test drinking water fixtures every three years, which provide a framework for other higher education institutions in responding to lead contamination.
More Related Videos
11:19Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
Published on: March 7, 2016
07:32Use of Galvanic Skin Responses, Salivary Biomarkers, and Self-reports to Assess Undergraduate Student Performance During a Laboratory Exam Activity
Published on: February 10, 2016
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation and Co-precipitation