Related Experiment Video
Updated: Jun 25, 2025

Setup of Capillary Electrophoresis-Inductively Coupled Plasma Mass Spectrometry CE-ICP-MS for Quantification of Iron Redox Species FeII, FeIII
Published on: May 4, 2020
Precise measurement of Fe isotopes in marine and biological samples by pseudo-high-resolution multi-collector
Nang-Htay Yin1, Pascale Louvat2, Hugues Preud'homme2
1Universite de Pau Et Des Pays de L'Adour, E2S UPPA, CNRS, IPREM, Institut Des Sciences Analytiques Et de Physico-Chimie Pour L'Environnement Et Les Matériaux, Technopole Hélioparc, 2 Avenue du Président Pierre Angot, 64053, Pau, France. nang-htay.yin@univ-pau.fr.
Abstract:
This paper introduces an enhanced technique for analyzing iron isotopes in complex marine and biological samples. A dedicated iron purification method for biological marine matrices, utilizing three ion exchange columns, is validated. The MC-ICPMS in pseudo-high-resolution mode determines precise iron isotopic ratios, with sensitivity improved through the DSN-100 desolvating nebulizer system and Apex-IR. Only 2 µg of iron on DSN versus 1 µg on Apex is needed for six replicates (30-60 times improvement) while 10 to 20 µg is required for a single measurement on a wet system considering the resolution power (Rp) is maintained at 11,000-13,000. The Ni-doping method with a Fe/Ni ratio of 1 yields more accurate isotopic ratios than standard-sample bracketing alone. Measurement reproducibility of triplicate samples from marine biological experiments on MC-ICPMS is ± 0.03‰ (2SD) for δ56Fe and ± 0.07‰ for δ57Fe (2SD). This study introduces a novel iron purification process specifically designed for marine and biological samples, enhancing sensitivity and enabling more reliable measurements with smaller sample sizes and reduced uncertainties. It proposes iron isotopic compositions for biological reference materials, offering a valuable reference dataset in diverse scientific disciplines.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
High-Resolution Mass Spectrometry (HRMS)
Mass Analyzers: Common Types