Related Experiment Video
Updated: Jun 25, 2025

Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
Correlation between the radial artery resistance index and the systemic vascular resistance index: a cross-sectional
Edith Elianna Rodríguez Aparicio1, David Fernando Almanza Hernández2, Cristhian Rubio Ramos2
1Critical and Intensive Care Medicine, Escuela de Medicina y Ciencias de la Salud, Universidad del Rosario, Bogotá, Colombia.
Introduction:
Ultrasound measurement of the radial resistance index (RRI) in the anatomical snuffbox has been proposed as a useful method for assessing the systemic vascular resistance index (SVRI). This study aims to establish the correlation between SVRI measured by pulmonary artery catheter (PAC) and RRI.
Methods:
A cross-sectional study included all consecutive patients undergoing postoperative (POP) cardiac surgery with hemodynamic monitoring using PAC. Hemodynamic assessment was performed using PAC, and RRI was measured with ultrasound in the anatomical snuffbox. The Pearson correlation test was used to establish the correlation between RRI and SVRI measured using PAC. Hemodynamic behavior concerning RRI with a cutoff point of 1.1 (described to estimate under SVRI) was examined. Additionally, consistency between two evaluators was assessed for RRI using the intraclass correlation coefficient and Bland-Altman analysis.
Results:
A total of 35 measurements were obtained. The average cardiac index (CI) was 2.73 ± 0.64 L/min/m², and the average SVRI was 1967.47 ± 478.33 dyn·s·m²/cm5. The correlation between RRI and SVRI measured using PAC was 0.37 [95% CI 0.045-0.62]. The average RRI was 0.94 ± 0.11. RRI measurements > 1.1 had a mean SVRI of 2120.79 ± 673.48 dyn·s·m²/cm5, while RRI measurements ≤ 1.1 had a mean SVRI of 1953.1 ± 468.17 dyn·s·m²/cm5 (p = 0.62). The consistency between evaluators showed an intraclass correlation coefficient of 0.88 [95% CI 0.78-0.93], and Bland-Altman analysis illustrated adequate agreement of RRI evaluators.
Conclusions:
For patients in cardiac surgery POP, the correlation between the SVRI measured using PAC and the RRI measured in the anatomical snuffbox is low. Using the RRI as a SVRI estimator for patients is not recommended in this clinical scenario.
Related Concept Videos
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation