Related Experiment Video
Updated: Jun 25, 2025

Clinical Protocol of Producing Adipose Tissue-Derived Stromal Vascular Fraction for Potential Cartilage Regeneration
Published on: September 29, 2018
Hypersensitive Reaction of Oxidized Regenerated Cellulose Powder in Total Knee Arthroplasty
Yoshinori Mikashima1, Hitoshi Imamura1, Yoshiko Shirakawa1
1Oume Knee Surgery Center, Takagi Hospital, Tokyo, JPN.
Abstract:
The powdered form of oxidized regenerated cellulose (ORC powder) is a widely used biodegradable hemostatic material in the field of surgery. There are several reports of its effectiveness and safety; however, excessive foreign body reactions remain a concern for surgeons in total knee arthroplasty (TKA). A 70-year-old woman who underwent unilateral TKA using ORC powder to control perioperative blood loss exhibited a skin rash around her operated knee at six days postoperatively. These reactions were potentially hypersensitive to ORC powder. After receiving antiallergic medication for 18 days, the skin rash disappeared. Although there are several reports on the safety of ORC powder, inadequate intraoperative lavage of the product may induce hypersensitive reactions such as skin rash.