Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Quality Control01:05

Quality Control

160
Quality control is one of the three cyclical quality assurance activities that help keep a system under statistical control. Typical quality control activities include creating quality control charts, conducting proficiency testing, and documenting and archiving results.
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
160
Receiver Operating Characteristic Plot01:15

Receiver Operating Characteristic Plot

138
A ROC (Receiver Operating Characteristic) plot is a graphical tool used to assess the performance of a binary classification model by illustrating the trade-off between sensitivity (true positive rate) and specificity (false positive rate). By plotting sensitivity against 1 - specificity across various threshold settings, the ROC curve shows how well the model distinguishes between classes, with a curve closer to the top-left corner indicating a more accurate model. The area under the ROC curve...
138
Detection of Gross Error: The Q Test01:00

Detection of Gross Error: The Q Test

6.1K
When one or more data points appear far from the rest of the data, there is a need to determine whether they are outliers and whether they should be eliminated from the data set to ensure an accurate representation of the measured value. In many cases, outliers arise from gross errors (or human errors) and do not accurately reflect the underlying phenomenon. In some cases, however, these apparent outliers reflect true phenomenological differences. In these cases, we can use statistical methods...
6.1K
Data Validation01:15

Data Validation

161
Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
161
Quality Assurance01:19

Quality Assurance

123
Quality assurance is the overarching term used to describe the activities employed to ensure the proper performance of a system. These activities can be classified into three categories: quality control, quality assessment, and internal corrective measures. Typically, these activities work cyclically: quality control is performed before and during the analysis, while quality assessment occurs during and after the investigation. Internal corrective measures are implemented based on the findings...
123
Sensitivity, Specificity, and Predicted Value01:13

Sensitivity, Specificity, and Predicted Value

289
In healthcare diagnostics, laboratory tests play a crucial role in identifying and diagnosing a wide range of medical conditions. However, interpreting test results is not always straightforward. An abnormal test result does not always confirm the presence of a disease, just as a normal result does not guarantee its absence. To assess the reliability of these diagnostic tools, healthcare practitioners rely on two key statistical indicators: sensitivity and specificity.
Sensitivity is the...
289

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Likelihood ratios of quantitative diagnostic test results.

Scandinavian journal of clinical and laboratory investigation·2026
Same author

Interpreting two test results of one analyte from the same individual using bivariate reference values.

Scandinavian journal of clinical and laboratory investigation·2026
Same author

Divide or subtract: transferrin saturation versus unbound iron binding capacity (UIBC).

Scandinavian journal of clinical and laboratory investigation·2026
Same author

Testing MMA<sub>100</sub> - the eGFR-adjusted concentration of methylmalonic acid in plasma.

Scandinavian journal of clinical and laboratory investigation·2025
Same author

Imperfect reference standards cause biased likelihood ratios.

Scandinavian journal of clinical and laboratory investigation·2025
Same author

Stability of 17 endocrine analytes in serum or plasma after four cycles of repeated freezing and thawing.

Scandinavian journal of clinical and laboratory investigation·2025

Related Experiment Video

Updated: Jun 25, 2025

Author Spotlight: Validation of SICOLE-R for Assessing Cognitive and Reading Skills in Spanish-Speaking Children and Its Role in Personalized Education
09:00

Author Spotlight: Validation of SICOLE-R for Assessing Cognitive and Reading Skills in Spanish-Speaking Children and Its Role in Personalized Education

Published on: August 16, 2024

753

The diagnostic accuracy of quality control rules.

Arne Åsberg1, Bjørn Johan Bolann2,3

  • 1Department of Clinical Chemistry, St. Olav's Hospital, Trondheim, Norway.

Scandinavian Journal of Clinical and Laboratory Investigation
|May 28, 2024
PubMed
Summary

Quality control rules in clinical chemistry can be optimized using ROC curves. Mean rules with N=2 outperform Westgard rules, reducing false alarms and improving error detection for better patient safety.

Keywords:
Allowable biasROC curve analysisdecision analysislikelihood ratioquality control rules

More Related Videos

Detection of Antibodies That Neutralize the Cellular Uptake of Enzyme Replacement Therapies with a Cell-based Assay
07:52

Detection of Antibodies That Neutralize the Cellular Uptake of Enzyme Replacement Therapies with a Cell-based Assay

Published on: September 10, 2018

8.8K
Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
06:16

Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease

Published on: August 9, 2024

398

Related Experiment Videos

Last Updated: Jun 25, 2025

Author Spotlight: Validation of SICOLE-R for Assessing Cognitive and Reading Skills in Spanish-Speaking Children and Its Role in Personalized Education
09:00

Author Spotlight: Validation of SICOLE-R for Assessing Cognitive and Reading Skills in Spanish-Speaking Children and Its Role in Personalized Education

Published on: August 16, 2024

753
Detection of Antibodies That Neutralize the Cellular Uptake of Enzyme Replacement Therapies with a Cell-based Assay
07:52

Detection of Antibodies That Neutralize the Cellular Uptake of Enzyme Replacement Therapies with a Cell-based Assay

Published on: September 10, 2018

8.8K
Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
06:16

Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease

Published on: August 9, 2024

398

Area of Science:

  • Clinical Chemistry
  • Laboratory Quality Control
  • Statistical Process Control

Background:

  • Internal quality control (IQC) in clinical chemistry laboratories relies on control materials to monitor analytical performance.
  • Quality control rules are employed to interpret control results and detect systematic errors, aiming for high error detection probability (Ped) and low false rejection probability (Pfr).

Purpose of the Study:

  • To represent quality control rules as points on a Receiver Operating Characteristic (ROC) curve by varying the control limit.
  • To introduce a novel method for selecting the optimal control limit, analogous to diagnostic test ROC analysis.
  • To compare the performance of mean rules against Westgard rules using ROC curve analysis.

Main Methods:

  • Quality control rules were analyzed using ROC curves, plotting Ped against Pfr with varying control limits.
  • A decision-making framework for optimal control limit selection was proposed, considering pretest error probability, detection benefit, and false alarm cost.
  • Performance comparison between mean rules and Westgard rules for N=2 was conducted via ROC curve analysis and evaluation of Max E(NUF).

Main Results:

  • ROC curve analysis demonstrated that mean rules (N=2) outperform Westgard rules, as their ROC curve lies above that of Westgard rules.
  • Mean rules exhibited a lower maximum expected increase in unacceptable patient results during out-of-control conditions (Max E(NUF)) compared to comparable Westgard rules.

Conclusions:

  • ROC curve analysis provides a robust framework for evaluating and optimizing quality control rules in clinical chemistry.
  • Mean rules with N=2 offer superior performance over Westgard rules in terms of error detection and minimizing the impact of out-of-control events on patient results.