Related Experiment Video
Updated: Jun 25, 2025

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
CAD-CAM pressure-exerting device to create an ovate pontic for an implant-supported fixed partial denture
Zhen Yang1, Dong Lin2, Jianguo Tan3
1Assistant Professor, Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices& Beijing Key Laboratory of Digital Stomatology & NHC Key Laboratory of Digital Stomatology & NMPA Key Laboratory for Dental Materials, Beijing, PR China.
Abstract:
This article presents a digital approach to fabricating a computer-aided design and computer-aided manufacturing (CAD-CAM) ovate pontic creating device for an implant-supported fixed partial denture. Intraoral digital scanning was done after osseointegration, and the pontic was designed as 2 separate parts, with the fixed part connecting the coronal part of the restoration and an ovate former shaping the pontic area. A mechanical spring was placed between the 2 parts to exert consistent pressure on the ovate former. An ovate pontic can be individually created rapidly and precisely as designed with this novel CAD-CAM device. This technology can be used to personalize the gingival morphology, improve esthetics, and minimize discomfort during the procedure.