Narrowband room temperature phosphorescence of closed-loop molecules through the multiple resonance effect

Xiaokang Yao1,2, Yuxin Li1, Huifang Shi1

  • 1Key Laboratory of Flexible Electronics (KLoFE) & Institute of Advanced Materials (IAM), School of Flexible Electronics (Future Technologies), Nanjing Tech University (NanjingTech), Nanjing, China.

PubMed

Related Concept Videos

Photoluminescence: Fluorescence and Phosphorescence01:23

Photoluminescence: Fluorescence and Phosphorescence

Photoluminescence is a process where a molecule absorbs light energy and re-emits it in the form of light. This phenomenon occurs when a substance absorbs photons, promoting its electrons to higher energy level excited states, followed by a relaxation process in which the electrons return to their original ground state energy levels and emit light. Photoluminescence is widely observed in various materials, including semiconductors, and organic and inorganic compounds.
A pair of electrons in a...
2.0K
Variables Affecting Phosphorescence and Fluorescence01:26

Variables Affecting Phosphorescence and Fluorescence

Fluorescence and phosphorescence are essential phenomena in fields like analytical chemistry, biological imaging, and materials science, where they detect molecular properties and visualize cellular structures. Understanding the variables that influence these luminescent behaviors is crucial for maximizing accuracy and efficiency in their applications. These variables can broadly be grouped into chemical structure, solvent properties, and external conditions, each playing a distinct role in...
497
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
387
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
580
Molecular Spectroscopy: Absorption and Emission01:14

Molecular Spectroscopy: Absorption and Emission

Molecules possess discrete energy levels called quantum states. Unlike atoms, which have simpler energy levels, molecules possess additional rotational and vibrational energy levels.  Each energy level is separated by an energy gap, with the gaps between adjacent electronic, vibrational, and rotational levels varying significantly. The three types of energy levels in a diatomic molecule are shown in Figure 1.
2.3K
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
198