Related Experiment Video
Updated: Jun 25, 2025

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
A conservative approach to localize loose implant screw through cemented crown: an in vitro experimental study
Kale Masoud Mohammad Saeed1, Abdulsalam Rasheed Al-Zahawi2
1Department of Conservative Dentistry, College of Dentistry, University of Sulaimani, Sulaimaniyah, 46001, Iraq. kale.mohammad@univsul.edu.iq.
Background:
Retrieval of cement-retained implant-supported restorations is intriguing in cases of screw loosening. Detecting the estimated size of the screw access hole (SAH) could decrease destruction to the prosthesis and preserve the crown.
Objectives:
To precisely localize loose implant screws through cemented crowns to reduce crown damage after screw loosening.
Materials And Methods:
In this in vitro study, 60 cement-retained implants supported 30 zirconia-based, and 30 ceramics fused to metal (CFM) lower molar crowns were invented, and each was subdivided into three subgroups (10 each). In group I (AI/BI) (control), SAH was created with the aid of orthopantomography (OPG). In contrast, in group II (zirconia-crown), SAH was created with the aid of CBCT + 3D printed surgical guide with a 2 mm metal sleeve in subgroups IIA/IIIA and CBCT + MAR was used to develop SAH in subgroups IIB/IIIB. SEM and Micro-CT scanned the SAH openings to determine the diameter of the hole, cracking, chipping, and chipping volume.
Results:
Regarding the effect of plane CBCT and CBCT + MAR on prepared crowns, a highly significant association between group I with group II (p = 0.001) and group III (p = 0.002) was detected. Regarding the cracking of SAH, significant differences between the zirconium crown and CFM restoration (p = 0.009) were found, while for the chipping, no significant association was seen between groups (p = 0.19).
Conclusions:
CBCT, either as a plane CBCT or with MAR, significantly improved the accuracy of drilling the screw channel and decreased injury to the existing restoration and abutment, aiding in better localization of SAH in loosened implant abutment screws.
More Related Videos
12:19Multi-Scale Modification of Metallic Implants With Pore Gradients, Polyelectrolytes and Their Indirect Monitoring In vivo
Published on: July 1, 2013
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024