Auditory brainstem implants: an analysis of adverse events in the MAUDE database
Olivia E Speed1, Soroush Farsi1, Kaersti Rickels1
1University of Arkansas for Medical Sciences - Little Rock, AR, USA.
Objective:
Auditory Brainstem Implants (ABI) are used to restore hearing in patients lacking appropriate cochlear anatomy and/or cochlear nerve. The objective of this study was to examine the Manufacture and User Facility Device Experience (MAUDE) database to analyze adverse events.
Study Design:
This is a study of a multi-institutional database maintained by the US FDA.
Setting:
A database analysis was performed via collaboration of multiple clinicians at tertiary referral centers.
Methods:
The MAUDE database was queried for Medical Device Reports (MDRs) relating to ABIs. MDRs were identified using the advanced search term "Implant, Auditory Brainstem" and reviewing all reports with the basic search term "Brainstem Implant". All collected reports were individually reviewed.
Results:
A total of 265 individual patient reports were reviewed, of which 55 reports met inclusion criteria. Reports regarding audiologic outcome included failure to provide hearing benefit (n = 27), implant failure/device malfunction (n = 10), and device non-use (n = 6). Postoperative complications included local skin infection (n = 3), CSF leak (n = 3), elevated ICP (n = 1), surgical site dehiscence (n = 1), swelling (n = 1), seroma formation requiring drainage (n = 1), and meningitis (n = 2). Two patients had dislodged magnets during 1.5 Tesla MRI acquisition. There were 35 instances of full explantation of the device and 1 partial removal; 13 patients had a new device implanted following explantation.
Conclusions:
Poor hearing results, device failure, and non-use were commonly reported causes for explanation in this analysis. This information can aid physicians in counseling patients and family members and managing device expectations.
Related Concept Videos
Nonsense-mediated mRNA Decay
Usually, Upf3 binds to an Exon Junction Complex (EJC) at mRNA splice sites. If a ribosome fully translates the mRNA,...
Mismatch Repair
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
Errors occurring during blood pressure monitoring
Several factors...
Pharmacovigilance
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
Therapeutic Drug Monitoring: Affecting Factors
Censoring Survival Data