High-throughput color determination of red raspberry puree and correlation of color parameters with total
Claudia Baldassi1, Clover Lee1, Michael Dossett2
1Wine Research Centre, Faculty of Land and Food Systems, The University of British Columbia, 2205 East Mall, Vancouver, BC, V6T 1Z4, Canada.
Background:
Red raspberry fruit color is a key driver of consumer preference and a major target of breeding programs worldwide. Screening for fruit color typically involves the determination of anthocyanin content and/or the assessment of color through a colorimeter. However, both procedures are time-consuming when the analyses involve hundreds or thousands of samples. The objectives of this study were to develop a high-throughput method for red raspberry puree color measurement and to test the correlations between color parameters and total anthocyanin content. Color coordinates were collected with a colorimeter on 126 puree samples contained in Petri dishes and with the Tomato Analyzer Color Test (TACT) module to assess the same samples prepared in Petri dishes and in 96-well plates. An additional 425 samples were analyzed using only 96-well plates. Total anthocyanins were extracted from all 551 samples.
Results:
Regression models for L*, a*, b* measured with the colorimeter and TACT using Petri dishes were all significant (p < 0.001), but very consistent only for L* (R2 = 0.94). Significant (p < 0.001) and very consistent regressions (R2 = 0.94 for L* and b*, R2 = 0.93 for a*) were obtained for color parameters measured with TACT using Petri dishes and TACT using plates. Of the color parameters measured with the colorimeter, only L*, a*/b*, and hue significantly correlated with total anthocyanins (p < 0.05), but, except for L* (R = - 0.79), the correlations were weak (R = - 0.23 for a*/b* and R = 0.22 for hue). Conversely, all correlations with total anthocyanins and color parameters measured with TACT were significant (p < 0.001) and moderately strong (e.g., R = - 0.69 for L* and R = 0.55 for a*/b*). These values were indicative of darker colors as total anthocyanin content increased.
Conclusions:
While the colorimeter and TACT-based methods were not fully interchangeable, TACT better captured color differences among raspberry genotypes than the colorimeter. The correlations between color parameters measured with TACT and total anthocyanins were not strong enough to develop prediction models, yet the use of TACT with 96-well plates instead of Petri dishes would enable the high-throughput measurement of red raspberry puree color.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
07:41Author Spotlight: An Alternative Approach to Protein Quantification by Bradford Assay Using a Smartphone
Published on: September 8, 2023
Related Concept Videos
Indicators
Redox Titration: Overview
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Atomic Emission Spectroscopy: Overview
Color Vision
