Abstract:
Sputum suction is a necessary measure to remove respiratory secretions and collect sputum specimens, and the traditional sputum suction device includes open and closed methods. However, the open sputum suction device can easily cause sputum splashing during operation, polluting the operator and the surrounding environment. The closed sputum suction device is more expensive than the open sputum suction device. Although it can be used repeatedly, the friction between the protective sleeve and the wall of the suction tube increases after repeated uses, which in turn affects the operation. In addition, the two sputum suction methods need to be connected to a sputum collector when the sputum specimen is collected. This process can easily lead to leakage and contamination of specimens, and at the same time increase the infection risk for patients. In order to overcome the above problems, the medical staff from the department of critical care medicine of the First Affiliated Hospital of Dalian Medical University invented a new type of switchable semi-closed sputum suction device, and obtained the National Utility Model Patent of China (ZL 2020 2 1564712.3). The device is composed of a suction device connection port, a sliding negative pressure switch, an adapter interface, a pipe body, a transparent film protective sleeve, a clip-on connection joint, and a sputum collector. The sliding negative pressure switch at the connection port of the suction device can realize one-person one-handed operation. The sputum collector is connected with the sputum suction device to ensure that the specimen is not exposed. The transparent film protective sleeve covers the sputum suction tube body to ensure that the whole process of sputum suction operation is pollution-free. The clip-on connection joint is connected with the artificial airway interface to avoid sputum splashing during sputum suction, and it is clamped immediately after operation to reduce environmental pollution. Compared with the existing sputum suction device, the new switchable semi-closed sputum suction device has a more reasonable design and lower cost, which is worthy of clinical promotion.
Related Concept Videos
Tracheostomy Suctioning II: Procedure
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...