Related Experiment Video
Updated: Jun 25, 2025

OnePot PURE Cell-Free System
Published on: June 23, 2021
Rapid purification and scale-up of tilianin using counter-current chromatography with rectangular horizontal tubing
Shunjie Zhang1, Xinjie Xiang1, Yongan Hu2
1Department of Emergency Medicine and Laboratory of Emergency Medicine, West China Hospital, West China School of Medicine, Sichuan University, Chengdu, 610041, China.
Abstract:
In counter-current chromatography (CCC), linear scale-up is an ideal amplification strategy. However, when transferring from analytical to predictable preparative processes with high throughput, linear scale-up would be challenging due to limitations imposed by differences in instrument parameters, such as gravitational forces, tubing cross-section area, tubing length, column volume and flow rate. Some effective scale-up strategies have been studied for different instrument parameters, but so far, these scale-up works have only been tested on standard circular (SC) tubing. The previous research of our group found that rectangular horizontal (RH) tubing can double the separation efficiency compared with conventional SC tubing, and has industrial production potential. This paper used the separation of tilianin from Dracocephalum moldavica L. as an example to demonstrate how to scale up the optimized process from analytical SC tubing to preparative RH tubing. After systematic optimization of solvent systems, sample concentration and flow rate on the analytical CCC, the optimized parameters obtained were successfully transferred to the preparative CCC. The results showed that a crude sample of 2.07 g was successfully separated using a solvent system of n-hexane - ethyl acetate - ethanol - water (1:4:1:5, v/v/v/v) in reversed phase mode, and the three consecutive separations produced a total of 380 mg tilianin in 75 min with high purities of 98.3%, as analyzed by HPLC. The total throughput achieved from the analytical to semi-preparative scale was improved by 138 times (from 12 mg/h to 1.66 g/h), while the column volume was increased by only 46.5 times (from 15.5 mL to 720 mL). This is the successful application of CCC for the separation and purification of tilianin. Given that SC tubing is the traditional configuration for CCC columns, this study is a necessary step to prove the applicability of RH tubing columns for routine use and potential large-scale industrial applications.
Related Concept Videos
Principles Of Column Chromatography
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: