Related Experiment Video
Updated: Jun 25, 2025

Intraoperative Visualization of Subretinal Injection and Retinal Detachment in Rats
Published on: March 7, 2025
Sharper vision, steady hands: can robots improve subretinal drug delivery? Systematic review
Paweł Marek Łajczak1, Zbigniew Nawrat2,3
1Zbigniew Religa Student Scientific Club at Department of Biophysics, Faculty of Medical Sciences in Zabrze, Medical University of Silesia in Katowice, Jordana 18, 40-043, Zabrze, Poland. pawel.lajczak03@gmail.com.
Abstract:
Subretinal injection (SI) is a novel drug delivery method, directly to retina for treatment of various eye disease. However, manual injection requires surgical experience and precision due to physiological factors. Robots offer solution to this issue, by reducing hand tremor and increased accuracy. This systematic review analyzes current status on robot-assisted SI compared to conventional techniques. Systematic search across 5 databases was conducted to identify studies comparing manual and robot-assisted SI procedures. Extracted data included robotic systems, complications, and success rates. Four studies, including one human trial, two ex vivo porcine eye studies, and one artificial eye model study were included in the synthesis. The findings show early advantages of robot-assisted SI. Compared to traditional interventions, robot procedures result in reduced tremor, what potentially lowers the risk of complications, including retinal tears and reflux. The first in-human randomized trial showed encouraging results, with no significant differences in surgical times or complications between robot-assisted and manual SI. However, major limitation of robot-assisted procedures is longer procedure time. Robot-assisted SI holds promise by offering increased precision and stability, reducing human error and potentially improving clinical outcomes. Challenges include cost, availability, and learning curve. Overall, early stage of robot-assisted SI suggests advantages in precision, complication reduction, and potentially improved drug delivery. Further research in human randomized trials is needed to fully assess its full-scale clinical application.
More Related Videos
07:49Slow-release Drug Delivery through Elvax 40W to the Rat Retina: Implications for the Treatment of Chronic Conditions
Published on: September 17, 2014
07:13An Alternative and Validated Injection Method for Accessing the Subretinal Space via a Transcleral Posterior Approach